About the water softener system.
SET
Service: Regeneration and Heavy Duty Backwash
NOTE:Each of the following functions has a factorg-set default value. The defaults are: Regeneration start time
-2:00AM; HaƗimum dags between regenerations-O (displag shows dY-); Efficiencgmode-ON; Heavg dutg
backwash -OFF. The defaults are suitable for most installations. However, depending on water supplg qualitg,
household peak water use hours, etc., adjustment is available to meet specific needs. To make a change, read
and do the following.
Regeneration (Start) Time: Atthe 2:00 AH regeneration start time, the water softening sgstem begins
regeneration at that time, ending at about 4:00 AH.This is a good time in most households because water is not
in use(seeAutomatic Hard Water BypassDuringRegenerationsection).If a different time would be better for gour
needs,do stepsZ,2,3,5,7,9 and 11 belowto changethe starting hour.
Maximum Days Between Regeneration: Thedefault setting (dY-)allows the timer to control regeneration
frequencg basedon water usage readingsfrom the water meteEIt providesthe most economical operation.
You can set a maximum time (indabs)between regenerations.Forexample, no more than three dabs will pass
without a regeneration occurring if gou set dY3 in the displag.A ! to 7 dab setting isavailable.To make a
change from the default setting, do steps Z,3,4,5,7,9 and !1 below.
Efficiency Mode: Whenthis feature isON,the unit will operate at salt efficienciesof 4000 grainsof harness per
pound of salt or higheE(Hag recharge more often usingsmaller salt dosage and lesswater).Whenthis isON,
the efficiencg icon_ will show in the lower right hand comer of the displag.To make a change for the
default setting, do steps !, 3,5,6,7,9 and !! below.
Heavy Duty Backwash: When set to ON,the backwash cgcle of regeneration will be 10 minutes long instead
of the normal seven minute length.This isbeneficial on some water supplies high in iron or sediment content.
Toconserve water,on clean supplies,be surethe default setting OFFshows.Tochange this setting, do steps !,
3,5,7,8,9 and !1 below.
Auto Regeneration When Capacity is Lo_. Thesoftener will regenerate at the regeneration time onlg.
Although the control hasa look-forward feature which anticipates normal demand, an unusuallg high usage
mag result ina lossof softening capacitg. Turning the feature ONwill cause the softenerto go into a
regeneration cgclewhen 97% ofthe softening capacitg has beenused.Tochange settings,do steps1,3,5,7,9,
10 and 11 below.
[] Beginningfrom the presenttime displag, pressand hold in the SETbutton until _ beginsto flash.
[_ Pressthe UPor DOWN button to displogthe desiredstart time.The UPbutton movesthe time ahead;the
DOWN button movesthe time backward.
[] Pressthe SETbutton again,and _ flashes.
[_To set a maximum time {indabs)between regenerations, pressthe UPor DOWN button.
[] Pressthe SETbutton again and the ONflashesand the efficiencg mode icon
shows in the lower right hand corner of the screen.
[_Use the UPor DOWN arrows to toggle the efficiencg mode either ONor OFF.
[] Pressthe SETbutton to displag _.
[_Use the UPbutton to change the displagto ON to increase the backwash time, if desired.
[] Pressthe SETbutton _ and _ alternatelg flashes.
[_Use the UPbutton to turn Auto Regeneration cgcle to ON.
[_ Pressthe SETbutton a final time to return to present time of daB.