Dewalt DXPW60606 HONDA With CAT Triplex Plunger Pump Cold Water Professional Gas Pressure Washer 4200 PSI at 4.0 GPM

INSTRUCTION MANUAL - Page 14

For DXPW60606.

PDF File Manual, 68 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
14
English
-
fler during or immediately after use of your pressure washer.
Damage to hoses from contact with hot engine surfaces will
NOT be covered by warranty.
NOTICE: Never pull water supply hose to move pres sure washer.
This could damage hose and/or pump inlet.
DO NOT use hot water, use cold water only.
 turn water supply off while pressure washer engine is
running or damage to pump will result.
DO NOT stop spraying water for more than
T
two minutes at a time. Pump operates in
bypass mode when spray gun trigger is not
pressed. When the temperature inside the pump
rises too high the thermal relief valve (T) will open
and release a gush of water in an effort to lower
the temperature inside the pump. The thermal
relief valve will then close. If pump is left in bypass mode for
more than two minutes internal components of the pump can
be damaged.
START-UP PROCEDURE
1.Inawell-ventilatedoutdoorarea,addfresh,high-quality,unleaded
gasoline with a pump octane rating of 86 or higher. Do not overfill.
Wipe up spilled fuel before starting the engine. Refer to engine
instruction manual for correct procedure.
2. Check engine oil level. Refer to the engine instruction manual for
correct procedure.
3. Connect the water hose to the water source. Turn the water source
on to remove all air from the hose. When a steady stream of water is
present, turn the water source off.
4. Verify the filter screen (U) is in water inlet of pump.
U
The cone side faces out.
5. Connect the cold water source (V) to pump inlet.
NOTE: Water source must provide a minimum of 5
gallons per minute at 20 psi (138 kPa).
WARNING: To reduce the possibility of
contamination always protect against backflow when
connected to a potable water system.
6. Connect high-pressure hose (P) to pump outlet.
V
P
7. If applying a chemical or cleaning solution,
refer to Chemicals and Cleaning Solvents.
8. Turn the water source on.
NOTICE: Risk of property damage. Failure to do
so could cause damage to the pump.
9. Remove all air from the pump and high pressure
hose by depressing trigger until a steady stream
of water is present.
10. Turn the engine ON/OFF switch (H) to the ON position.
11. Place the fuel valve lever (M) in the ON postion.
12.
If the engine is cold, move the choke (K) to the CLOSED position
as shown.
M
H
K
13.
WARNING: Risk of unsafe operation. Pull starter grip slowly
until resistance is felt. Then pull starter grip (I) rapidly to avoid
kickback and prevent hand or arm injury.
Loading ...
Loading ...
Loading ...