Frigidaire FES355ASF 30" Electric Slide-in Range

Installation Instructions - Page 3

For FES355ASF.

PDF File Manual, 28 pages, Read Online | Download pdf file

FES355ASF photo
Loading ...
Loading ...
1. Power Supply Cord Kit (U.S.A.)
The user is responsible for connecting the power supply
cord to the connection block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring" (flexible armored or
nonmetallic shielded copper cable), or by means of a
power supply cord kit. Only a power supply cord kit rated
at 125/250 volts minimum, 40 amperes and marked for
use with ranges shall be used. See chart for cord kit
connection opening size information. Cord must have
either 3 or 4 conductors. For mobile home installation, or
areas where local codes do not permit grounding through
neutral, a 4 conductor power supply cord kit rated at
125/250 volts minimum, 40 amperes and marked for use
with ranges should be used (see Figure 5).
Terminals on end of wires must be either closed loop or
open-end spade lugs with upturned ends. Cord must
have strain-relief clamp.
See below for 3 or 4 conductor wire connection.
Referto clsart below for proper range connection opening sizeand power
supply cord kit ampere rating information. Seeserialplate on appliance for
kilowatt rating data
See serial Plate on the
Appliance for KW Rating
120/240 Volts 120/208 Volts
0_87kw 0_78kw
8.8 - I6.5 kw 7.9_ 12 5 kw
t66_225 kw t26_185kw
Cord Kit
Ampere
Rating
30 Amp
40 Amp
50 Amp
Diameter (incises(cm))of
Appliance Connection Opening
Direct
Cord Kit Connection
11/8 (29) 7/8(22)
13/8 (35) 11/8 (2.9)
1 3/8 (35) 1 3/8 (3.5)
U.S.A. Style
Figure 1
Do not loosen the nuts which secure
the factory-installed range wiring to terminal block
while connecting range. Electrical failure or loss of
electrical connection may occur.
2. Factory Connected Power Supply
Cord (Canada only)
This range isequipped with a factory-connected power
cord (see Figure 2). Cord must be connected to a
grounded 120/240 volt or 120/208 volt range outlet. If
not outlet is available, have one installed by a qualified
electrician.
Canada Style
Figure 2
NOTE: Electric Slide-in Range is shipped from factory
with 1 1/8" (2.9 cm) dia. hole as shown on figure 4. If a
larger hole is required, punch out the knockout.
Risk of fire or electrical shock exists if
an incorrect size range cord kit is used, the
Installation Instructions are not followed, or the
strain relief bracket is discarded.
Electrical Shock Hazard
Electrical ground is required on this appliance.
Do not connect to the electrical supply until
appliance is permanently grounded.
Disconnect power to the circuit breaker or fuse
box before making the electrical connection.
This appliance must be connected to a
grounded, metallic, permanent wiring system,
or a grounding connector should be connected
to the grounding terminal or wire lead on the
appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.