Asko WCN311942G Wine Climate Cabinet

User Manual - Page 69

For WCN311942G.

PDF File Manual, 77 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Humidity out of range
CountermeasuresPossible cause
Try to minimize opening the door of the wine climate cabinet
appliance. Prepare loading plan of large quantities of bottles in
advance to minimize the required time for loading.
Frequent and/or long door
openings.
Try to use the ConnectLife mobile application as much as possible
to change appliance settings.
Making larger changes of the temperature settings may take the
appliance a few hours to reach new settings.
Recent big changes in
temperature settings.
Humidity levels in the appliance are strongly dependent on the
temperature changes and take longer to stabilize.
It may take a few hours for the appliance to cool to the requested
setting after being turned on.
Recent start-up of the
appliance.
Humidity levels in the appliance are strongly dependent on the
temperature changes and take longer to stabilize.
Make sure that the appliance is installed in a well ventilated room
and is not exposed to extremely high or extremely low temperatures.
Humidity levels in the appliance are strongly dependent on the
temperature changes and take longer to stabilize.
Extreme ambient
temperatures and/or humidity
levels.
For detailed appliance installation instructions please refer to the user
manual [see chapter Selecting the location].
In case of use in ambient with extremely high or extremely low
humidity levels you can purchase humidity stabilizer accessory set.
In case none of the above countermeasures helped and the "humidity out of range" warning persists,
please contact a service center.
Power failure
CountermeasuresPossible cause
If this power cut-outs appear to be frequent, contact professional
electrician to check electrical fuses, outlets and appliance's power
connecting cable.
Recent and/or frequent
power failure.
Error notifications
If a component inside the appliance is failing, a notification will pop-up.
The notification will display a code. Codes for these errors can be found in the table below.
DescriptionError
Code
Communication error from power board to user interface electronics.E0
Communication error from power board to wireless network card.E2
Communication error from wireless network card to power board.E3
Communication error from user interface electronics to power board.E8
69
Solving problems
Loading ...
Loading ...
Loading ...