Fuses
Fuses are on the left hand side of the machine
and are accessed by tilting the seat forward.
Fuses are at pin fuses type as used in
automobiles. The 20 A is the primary fuse. The
7.5 A is for the mower deck coupling.
Fuel Shut O󰀨 Valve
Blade Switch
To engage the mower deck, pull the knob out;
mower blades are disengaged when the knob is
pressed down.
Service Meter
Seat Adjustment Lever
(Applies to Z400X only)
Choke Control
The choke control is used for cold starts to give
the engine a richer fuel mixture. For cold starts,
pull the control up.
The service meter displays the total number of
hours the engine has run and shows when the
engine and mower need servicing.
After every 50 hours of operation, an oil can icon
will appear and stay on for two hours, before
an automatic reset occurs. To manually reset
the meter, turn the key o󰀨 and on ve times at
one second intervals. To service the engine and
mower, see the Service Journal of this manual.
Note: The service meter operates (clocks hours)
only when the engine is running. Be sure to turn
the key o when the unit is not in use, to prevent
meter hours from accumulating.
The seat can be adjusted lengthways. The lever
under the front edge of the seat is moved to the
left (as seen by the driver in the seat), to adjust
the seat backward or forward.
IMPORTANT INFORMATION Seat must not
be adjusted while unit is in motion.
The fuel shut o󰀨 valve is just forward of the rear
fuel tank mount bracket. The valve is o󰀨 when the
handle tab is turned perpendicular to the fuel line.