PowerSupplyCord DirectWire
FireHazard
UseanewULapproved30amppower
supplycord.
UseaULapprovedstrainrelief.
Disconnectpowerbeforemakingelectrical
connections.
Connectneutralwire(whiteorcenterwire)to
centerterminal(silver).
Groundwire(greenorbarewire)mustbe
connectedtogreengroundconnector.
Connectremaining2supplywiresto remaining
2terminals(gold).
Securelytightenallelectricalconnections.
Failureto dosocanresultindeath,fire,or
electricalshock.
FireHazard
Use10gaugesolidcopperwire.
UseaULapprovedstrainrelief.
Disconnectpowerbeforemakingelectrical
connections.
Connectneutralwire(whiteorcenterwire)to
centerterminal(silver).
Groundwire(greenorbarewire)mustbe
connectedtogreengroundconnector.
Connectremaining2supplywiresto remaining
2terminals(gold).
Securelytightenallelectricalconnections.
Failureto dosocanresultindeath,fire,or
electricalshock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
1 2 3 4
5
6
1. Terminal block cover
2. External ground connector
3, Center, silver-colored terminal block screw
4. Hold-down screw
5. Neutral grounding wire (green/yellow)
6, Hole below terminal block opening
3.
Assemble a 3/4in. (1.9 cm) UL approved strain relief (UL
marking on strain relief) into the hole below the terminal block
opening. Tighten strain relief screws just enough to hold the
two clamp sections together. Put power supply cord through
the strain relief, The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position.
4. Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)