Kenmore 11081422510 24'' ( 61cm) Wide Stacked Laundry Center Washer-Dryer

Use & Care Guide & Installation instructions - Page 6

For 11081422510. Also, The document are for others Kenmore models: 110.81422, 110.81432

PDF File Manual, 108 pages, Read Online | Download pdf file

11081422510 photo
Loading ...
Loading ...
Loading ...
ALTERNATE PARTS
Parts listed are available from your local Sears store or
Sears Service Center. For further information, please call
1=800=4=MY-HOME ® (1=800=469=4663).
If you have:
Laundry tub or
standpipe taller than
96" (2.4 m)
1" (25 mm)
diameter standpipe
Overhead sewer
Floor drain
You will need to buy:
Sump pump system (if not already
available)
2" (51 mm) diameter to 1" (25 mm)
diameter standpipe adapter,
Part Number 3363920
Standard 20 gal. (76 L) 34" (864 mm)
tall drain tub or utility sink and sump
pump (available from local plumbing
suppliers)
Siphon break, Part Number 285320,
additional drain hose, Part Number
285702, and connector kit, Part
Number 285442
Drain hose too short
Lint clogged drain
Water faucets
beyond reach
of fill hoses
Drain hose, Part Number 285664
and connector kit, Part Number 285442
Drain protector, Part Number 367031
2 longer water fill hoses:
6ft (1.8 m), Part Number 76314,
10 ft (3.0 m), Part Number 350008
LOCATION REQUIREMENTS
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Do not install in a garage.
Failure to do so can result in death, explosion, or fire.
You wlll need
[] A location that allows for proper exhaust installation. See
"Venting Requirements".
[] For 240 volt models, a separate 30-amp circuit. For 120 volt
models, a 120 volt, 60 Hz., AC only, 15- or 20-amp circuit.
[] If using a power supply cord on 240 volt models, and for 120
volt models, a grounded electrical outlet located within 2 ft.
(610 ram) of either side of the Laundry Center. See "Electrical
Requirements".
[] A sturdy floor to support the Laundry Center weight (Laundry
Center, water, and load) of 500 Ibs (226.8 kg).
[] A level floor with a maximum slope of 1" (25 mm) under
entire Laundry Center. Clothes may not tumble properly and
automatic sensor cycles may not operate correctly if Laundry
Center is not level. Installing on carpet is not recommended.
[] A water heater set to deliver 120°F (49°C) water to the washer.
[] Hot and cold water faucets located within 4ft (1.2 m) of the
hot and cold water fill valves, and water pressure of 5-100 psi
(34.5-689.6 kPa).
The Laundry Center must not be installed or stored in an area
where it will be exposed to water and/or weather.
6
Do not operate your washer in temperatures at or below 32°F
(0°C). Some water can remain in the washer and can cause
damage in low temperatures. See "Vacation, Storage, and Moving
Care" for winterizing information.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
Check code requirements. Some codes limit, or do not permit,
installation of the Laundry Center in garages, closets, mobile
homes, or sleeping quarters. Contact your local building inspector.
Installation Clearances
The location must be large enough to allow the dryer door
to open fully.
Laundry Center Dimensions
15 3/o"
(390 ram)
71%"
(1.82 m)
(816 ram)
*27 ¼" "_
(692 ram) *23 z/8"
(606 ram)
*Most installations require a minimum 5" (127 ram) clearance behind
the dryer for the exhaust vent with elbow. See "Venting Requirements".
Minimum spacing far recessed area or closet installation
The following spacing dimensions are recommended for this
Laundry Center. This Laundry Center has been tested for spacing
of 0" (0 mm) clearance on the sides, rear, and top. Recommended
spacing should be considered for the following reasons:
[] Additional spacing should be considered for ease of installation
and servicing.
[] Additional clearances might be required for wall, door, and
floor moldings.
[] Additional spacing on all sides of the Laundry Center is
recommended to reduce noise transfer.
[] For closet installation, with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
o oo o o
m
1"--_1N-26'/_"-_11_-_"
(25mm) (606ram) (25rnm)
A
_I"* 1-27'J,"÷I
(25mm) (692mm)
B
A. Recessed area
T (305turn}, __ 3!'(76mm)
48in,;< .-1
(310crn2) I_ t
(155cm2} I
'(76ram)
_.- 6"**
(127mm)
C
B. Side view -closet or confined area
C. Closet door with vents
*Required spacing
**Rear clearance may be 0" (0 mm) when house exhaust system
is lined up directly with dryer exhaust.