Fellowes AeraMax® Pro AM IV Air Purifier

Product Manual - Page 4

For AeraMax® Pro AM IV.

PDF File Manual, 14 pages, Read Online | Download pdf file

AeraMax® Pro AM IV photo
Loading ...
Loading ...
Loading ...
5
4
AM-PRO UI & INDICATOR LAYOUT
PROJECT:
DATE:
REV:
AUTHOR:
COPERFIELD
03-AUG-16
X4
M. GARTZ
OPERATION
The air purifier continuously works in automatic mode; the user can select which preference they would like the purifier to use based on the location or desired
operation of the air purifier. The purifier will operate through a minimized range of speeds, not exceeding the maximum level selected, in order to run quietly while
cleaning the room of contaminants. Once air is cleaned, and no sensors are activated, the unit lowers to energy saving mode to reduce energy consumption and
extend the life of the filters.
When Auto Mode is selected, the Auto mode indicator will be blue. This mode uses the EnviroSmart™ technology to monitor the air quality, motion and noise level
to adjust the fan speed in order purify your air as quickly as possible. Once air is cleaned, and no sensors are activated, the unit lowers to energy saving mode to
reduce energy consumption and extend the life of the filters.
When Quiet Mode is selected, the Auto Mode indicator will be purple. The machine will continue to use EnviroSmart™ but only utilizes the 3 lowest, most quiet of
the 5 fan speeds.
When Manual Mode is selected, the Manual mode indicator will be blue. This mode allows you to choose one of the 5 fan speeds and keep unit at this speed until
Auto Mode is chosen/selected. EnviroSmart™ sensors will NOT adjust the fan speed in this mode.
DISPLAY PANEL
HEPA FILTER REPLACEMENT INDICATORThis indicator will show
its status when the access panel is open or closed. If the light is red this indicates
the filter needs replacing. The replacement period will vary depending on the
filters used, hours of use, air quality, and rate of air flow. For filter replacement
indicator descriptions see FILTER REPLACEMENT INDICATORS section.
CARBON FILTER REPLACEMENT INDICATORThis indicator will
show its status when the access panel is open or closed. If the light is red this
indicates the filter needs replacing. The replacement period will vary depending
on the filters used, hours of use, air quality, and rate of air flow. For filter
replacement indicator descriptions see FILTER REPLACEMENT INDICATORS section.
ACCESSORY INDICATOR This indicator will show its status when the
access panel is open or closed. This indicator will only be used if an accessory filter
is installed in the unit. If the light is red this indicates the filter needs replacing.
The replacement period will vary depending on the filters used, hours of use, air
quality, and rate of air flow. For filter replacement indicator descriptions see FILTER
REPLACEMENT INDICATORS section.
AIR QUALITY SENSORThis indicator will show its status when the
access panel is open or closed. This indicator monitors the air quality and adjusts
the fan speed to keep your air purified. Blue, amber, and red lights indicate the
purity of your air.
PlasmaTRUE™ TECHNOLOGY This indicator will show its status when
the access panel is open or closed. Creates an ionized field to help safely remove
airborne pollutants. To turn on and off the PlasmaTRUE™ TECHNOLOGY, touch
and hold the PLASMA indicator. A blue light illuminates when the PlasmaTRUE™
TECHNOLOGY is enabled. To disable the PlasmaTRUE™ TECHNOLOGY, press and hold
“Plasma” indicator until light is off.
AUTO MODETo select, press and hold the button until the icon illuminates.
This mode uses the EnviroSmart™ technology to monitor the air quality, motion and
noise level to adjust the fan speed in order to purify your air as quickly as possible.
This button also includes QUIET MODE. To select, press and hold until the button turns
purple. The machine will continue to use EnviroSmart™ but only utilizes the 3 lowest,
most quiet of the 5 fan speeds.
MANUAL MODETo select, press the button until the icon illuminates. This
mode allows you to choose one of the 5 fan speeds and keep the unit at this speed
until AUTO MODE is chosen again. The internal sensors will not adjust the fan speed
in this mode.
FAN SPEED INDICATORSThe fan has 5 speeds and can reach turbo
speed to clean the room in case of high levels of contaminants. The number of bars
illuminated indicates fan speed.
1
5
2
6
3
7
8
4
1 2 3 4 5 6 7 8
NOTE: after the unit is turned on the “AQ” light will flash for a few minutes while the system self-calibrates.
1 – whisper
2 – low
3 – medium
4 – high
5 – turbo
CARE AND MAINTENANCE
CLEANING:
Clean external housing as necessary by wiping with a dry, soft cloth; for stains, use a warm, damp cloth.
Do not use volatile fluids such as benzene, paint thinner, scouring powder or other cleaners that may damage the unit surface.
Clean intake and exhaust vents by wiping with a dry, soft cloth.
Unlock access panel: to unlock, insert the
key provided and rotate counter-clockwise
¼ turn.
Touch and hold the illuminated
indicator for three seconds until
a beep is heard and the indicator
is flashing green.
Open front access panel by pressing latches
on both sides of unit. Allow panel to open
fully. Remove filter(s) to be replaced.
Release finger from indicator.
Remove any packaging wrap from the
new filters(s) and re-install the filters.
Touch and hold the indicator for three
seconds until a beep is heard and the
indicator light turns off.
1
FILTER REPLACEMENT INDICATORS:
The replacement filter indicators will signal when to replace the HEPA Filter and/or Carbon with Pre-Filter. The replacement period will vary depending on the hours of use, air
quality, and rate of air flow. However, under normal usage, most HEPA Filters need to be replaced every 2 years, and Carbon with Pre-Filter every 6 months. When a filter needs to
be replaced the following color will be shown on any one of the HEPA, CARBON, or ACCESSORY filter replacement indicators:
Red Flashing = RIGHT filter 90% full
Amber Flashing = LEFT filter 90% full
Red Flash, Pause, Amber Flash, Pause = Right & LEFT filters 90% full
Red = Replace RIGHT filter
Amber = Replace LEFT filter
Red & Amber Alternating = Replace Right & Left filters
Do not wash and reuse any of the filters – they will not work effectively. Only use AeraMax
®
PRO brand replacement filters as units will not function using any other replacements.
FILTER REPLACEMENT PROCEDURE:
FILTER REPLACEMENT:
When installing a new filter the unit will automatically detect the filter type but the user will have to manually reset the filter replacement indicators. To reset the flashing filter
replacement indicator use the following procedure:
TROUBLESHOOTING
PROBLEM: POSSIBLE SOLUTION:
The air quality control system fails to start.
Check to assure unit is connected to power supply.
Make sure filters are genuine AeraMax
®
PRO filters, as unit will not function with other
brands. IMPORTANT: Make sure filter detection area on genuine AeraMax
®
PRO
replacement filter aligns with window in filter frame.
Review “Re-Installing Filters” section for further detail.
Make sure front access panel is closed completely.
Make sure power switch is on.
The unit makes a faint ticking sound.
This indicates that the “PlasmaTRUE™” bipolar ionizer is working.
The HEPA and/or Carbon Filter replacement indicator light
remain lit after replacing the filter(s).
Repeat filter light reset instruction.
Note: If you do not complete step three within 10 seconds of completing step 1 then the indicator light will not be reset.
2
3
1
2 3
AeraMaxPRO_AMIV_AM4PC_410414_RevC_3L_050817.indd 4-5 5/10/17 9:03 AM
Loading ...
Loading ...
Loading ...