BRGC6001SS Brohn 60cm 4 Burner Gas Stainless Steel Cooktop

User Manual - Page 20

For BRGC6001SS.

PDF File Manual, 28 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
P a g e |
20
web: brohn.com.au
Place the clamp (B) over the holes that match the size of the screws. There are one
set of screw holes in each corner of the hob. Slightly tighten a screw (C) through the
clamp (B) so that the clamp is attached to the hob, but so that you can still adjust
the position of it.
Carefully turn the hob back over and then gently lower it into the aperture hole that
you have cut out.
On the underneath of the hob, adjust the clamps into a position that is suitable for
your worktop. Then fully tighten the screws (C) to secure the hob into position.
IMPORTANT INFORMATION
This hob is supplied to run on natural gas and cannot be used on any other type of
gas without modification.
Conversion for use on LPG and other gases must only be undertaken by a licensed
professional.
The hob must be installed by a qualified installer.
Failure to install the appliance correctly could invalidate warranty and lead to
prosecution under the local law and regulations.
VENTILATION REQUIREMENTS
The room containing the hob should have an adequate air ventilation.
The room must have opening windows or equivalent, some rooms may also require
a permanent vent.
If the room has a volume of less than 5m³, it will require an air vent of 100cm² in
effective area.
If the room has a volume between 5 and 10m³, it will require an air vent of 50cm²
unless it has a door which opens directly to the outside.
If it is installed in a room with a volume that exceeds 11m³, then no air vent is
required.
Consideration must be taken if there are any other fuel burning appliances in the
same room.
Ensure that the room containing the hob is well ventilated. Keep natural ventilation
holes or install a mechanical ventilation device such as a rangehood.
Prolonged intensive use of the appliance may call for additional ventilation, either
by the opening of a window, or by increasing the level of the mechanical
ventilation device (where present).