Refrigerator Water Filter Cartridge Model U KF8001AXX
Specifications
Service Flow Rate (Maximum) .............................................0.78 GPM (:2.9 L/rain)
Rated Service Life UKF8001AXX-750 (Maximum) ......750 gallons/2839 liters
Maximum Operating Temperature .....................................100° F/38 ° C
Minimum Pressure Requirement ........................................35 psi/241 kPA
Minimum Operating Temperature ......................................33° F/1 ° C
Maximum Operating Pressure .............................................100 psi/689 kPA
1000 Apollo Road
Eagan, Minnesota 55121-2240
651.450.4913
EPA EST #35917-MN-1
Performance Data
Parameter
Clllorine
T&O
Particulate**
100834/B
USEPA
MCL
Standard No. 42: Aesthetic Effects
Influent
Challenge Concentration
2.0 mg/L ± 10%
Min. Required
Reduction
50%
Influent
Average
1.88 mg/L
5,700,000 #/ml
Effluent
Average Maximum
<0.05 mg/L 0.06 mg/L
30,583 #/ml 69_000 #/ml
% Reduction
Average Minimum
>9726% 96.84%
99.52% 98.94%
at least 1O,000 particles/ml 85%
Standard No. 53: Health Effects
InfluentUSEPA
MCL
1 NTU _*
99.5% Reduction
99% Reduction
0.015 mg/L
0.015 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.003 mg/L
Influent
Effluent
Parameter Challenge ConcentmUon Average Average Maximum Average
Turbidi b, 11 ± 1 NTU*** 10.73 NTU 0.36 NTU .049 NTU 9709%
Cysts Minimum 5O,000/L 220,000 #/L <1 <1 >99.99o/o
Asbestos 107108 fibers/L; fibers >10 nlicrz)meters in length 155 MF/L <1 <1 >99.99%
Lead at pH 6.5 0.15 mg/L ± 10% 0.153 mg/L <.001 <.001 >99.35%
Lead at pH 8.5 0.15 mg/L ± 10% 0.150 mg/L <.001 <.001 >99.35%
Mercury at pH 5.5 .006 mg/L ± 10% 0.006 mg/L 0.00026 0.0005 98.72%
Mercury at pH 8.5 .006 mg/L ± 10% 0.006 mg/L 0.0008 0.0015 98.72%
Lindane 0.002 mg/L ± 10% 0.002 mg/L 0.000025 0.00007 98.72%
Toxaphene 0.015 mg/L ± 10% 0.015 mg/L <0.001 <0.001 92.97%
Atrazine 0.009 mg/L ± 10% .00873 mg/L <0.002 <0.002 76.99%
% Reduction
Minimum
95.20%
>99.99%
>99.99%
>99.35%
>99.35%
90.910/o
75.930/o
96.500/o
91.67%
75.310/o
Mini Required
Reduction
0.5 NTU
>99.95%
99%
0.10 mg/L
0.10 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.003 mg/L
* Tested using a flow rate of 0.78 GPM; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of
68 ° ± 5° F (20 ° ± 3 ° C] under standard laborato W conditions, however, actual
performance may vaiy. Health Clainl Perfornlance tested and certified by NSF
International
** Measurement in Particles/ml. Particles used were 0.5 - 1 microns
*** NTU - Nephelometric Turbidity units
Tested and certified by NSF International against ANSI/NSF Standards 42 & 53
in models UKFSOO1AXX-750 for the reduction of:
Standard No. 42: Aesthetic Effects | Standard No. 53: Health Effects
Taste and OdoT Reduction I Chenlical Reduction Unit
Chlorine Taste & Odo[ Lead, Atrazine, Lindane+ Mercury &
Mechanical Filtration Unit Toxaphene Reduction
Particulate Reduction Class 1 Mechanical Filtration Unit
CysL Turbidity and Asbestos Reduction
General Use Conditions
Read this Performance Data Sheet and compare the
capabilities of this unit with your actual water
treatment needs.
DO NOT use this product where water is micro-
biologically unsafe or of unknown quality without
adequate disinfection before or after the system.
System certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK
FOR COMPLIANCE WITH THE STATE AND LOCAL
LAWS AND REGULATIONS.
The PuriClean :_II retractable water filtration system
uses a UKF8001AXX replacement cartridge. Timely
replacement of filter cartridge is essential for
performance satisfaction from this filtration system.
Please refer to the applicable section of your Use &
Care Guide for general operation, maintenance
requirements and troubleshooting.
This system has been tested according to ANSI/NSF 42
and 53 for reduction of the substance listed above. The
concentration of the indicated substances in water
entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving
the system, as specified in ANSI/NSF 42 and 53.