1697092 Briggs and Stratton

User Manual - Page 10

For 1697092.

PDF File Manual, 48 pages, Read Online | Download pdf file

1697092 photo
Loading ...
Loading ...
Loading ...
Not for
Reproduction
10
OPERATION
False defect note:
When the battery is inserted into the charger and the status LED blinks RED,
remove the battery from the charger for 1 minute, then reinsert. If the status
LED blinks GREEN, then the battery is properly charging. If the status LED
is still blinking RED, remove the battery and unplug the charger for 1 minute.
After 1 minute, plug in the charger and reinsert the battery. If the status LED
blinks GREEN, then the battery is properly charging. If the status LED is still
blinking RED, the battery is defective and needs to be replaced.
CHARGER MOUNTING
1. This charger can be installed hanging on a wall using two #8 screws (not
included).
2. Locate the placement for the charger to be wall mounted.
3. If fastening to wood studs use 2 wood screws (not included).
4. For Charger BS2AC48: Drill two holes on center 3.63 in. apart ensuring that
they are vertically aligned.
5. If fastening to drywall use wall anchors (not included) and screws to secure
the charger to the wall.
6. This power unit is intended to be correctly orientated in a vertical or floor
mount position.
NOTE: If the battery and the charger won’t be used for a long time, remove the
battery from the charger and pull out the AC power plug.