201083 - 8500W DUAL FUEL ELECTRIC START GENERATOR
OPERATION
20
OPERATION
CO Shield
®
- Carbon Monoxide (CO) Detection
and Auto-shutoff System
The CO Shield
®
technology monitors the accumulation of
poisonous CO gas produced by engine exhaust when the generator
is running. If CO Shield detects elevated levels of CO gas, it
automatically shuts off the engine. Generators are intended to
be used outdoors, far away from occupied buildings and exhaust
pointed away from people and buildings.
If misused and operated in a location that results in the
accumulation of CO inside an enclosed or partially enclosed space,
for example a house, garage or a garage with the door partially
open, CO Shield will automatically shut off the generator and then
illuminate a red LED. Read the action label for what steps to take.
CO Shield is not a substitute for an indoor carbon monoxide
alarm.
1607-L-SF-C
AUTOMATIC SHUTOFF – YOU MUST:
APAGADO AUTOMÁTICOUSTED DEBE:
ARRÊT AUTOMATIQUE– VOUS DEVEZ :
Move generator to an open, outdoor area. Point exhaust away. Don’t run generators
in enclosed areas (e.g. not in house or garage).
Mover el generador a un área abierta a la intemperie. Apunte el escape alejado. No corra los
generadores en áreas cerradas (ej. no en una casa o garaje).
Déplacer le générateur vers un espace extérieur
en plein air. Garder l’échappement loin. Ne pas
faire fonctionner les générateurs dans un espace
clos (ex., pas dans une maison ou un garage).
ACTION LABEL
ETIQUETA DE ACCIÓN
ÉTIQUETTE D'ACTION
EXHAUST
EL ESCAPE
L’ECHAPPEMENT
POINT AWAY
DIRIJA ALEJADO
DIRIGER LOIN
Move to fresh air and get medical
help if sick, dizzy or weak.
Mueva al aire fresco y obtenga
asistencia medica si es
enfermo, mareado, o débil.
Aller à l'air frais et obtenir de
l'aide médicale si malade,
étourdi ou faible.
PROCESS
ColorsLPN 160 7-L-S F
Rev C
Size ~2 76.4 x 82.3 mm
Artwork Notes
2mm safe margin;
to be prin ted on white su bstrate
Revision Changes
B: Updated dieline
C: Delet ed “25 ft./ 7 m
This art work belongs to Champi on Power Equipment. T he contents are con dential and privile ged and shall not be disclo sed to or used by or for
outside par ties without t he explicit consent o f Champion Power Equ ipment.
K
485 152 109
When you approach the generator to investigate a shut off, a
blinking red LED light in the CO Shield area provides notification
that the generator shut off due to an accumulating CO hazard. The
red LED light will blink for at least five (5) minutes after a shutoff
event.
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOTICO
VEA ETIQUETA DE ACCIÓN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOTICO
VEA ETIQUETA DE ACCIÓN
SERVICE
REALICE UN SERVICIO
SERVICE
REALICE UN SERVICIO
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOMÁTICO
VEA ETIQUETA DE ACCIÓN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOMÁTICO
VEA ETIQUETA DE ACCIÓN
SERVICE
REALICE UN SERVICIO
SERVICE
REALICE UN SERVICIO
Move the generator to an open, outdoor area and point the
exhaust away from people and buildings. Once relocated to a safe
area, the generator can be restarted, and the proper electrical
connections made. Introduce fresh air and ventilate the location
where the generator shut off.
When starting, the red and yellow LED will blink ten (10) times
simultaneously to indicate the LED is working.
NOTICE
This blinking does not indicate CO Shield is working, as CO
Shield is working at all times the generator is running. Also,
the LED will not blink (10) times if the generator was restarted
within 1 minute after it was manually shut off. This does not
occur if generator shut off from a high CO event.
If CO Shield system experiences a fault and no longer provides
protection, the generator is shutoff automatically and the yellow
LED light will blink for at least five (5) minutes to notify you of the
fault.
Call our Technical Support Team at 1-877-338-0999 for repair.
The generator can be restarted, but will continue to shutoff.
CO Shield will detect the accumulation of carbon monoxide from
other fuel burning sources such as engine powered tools, or
propane heaters used in the area of operation. If another generator
is used and the exhaust is pointed at a CO Shield equipped
generator, the CO Shield may initiate a shutoff due to rising carbon
monoxide levels. This is not a fault. Hazardous carbon monoxide
has been detected. You must take action to move and direct the
equipment to better dissipate carbon monoxide far away from
people or buildings.
WARNING
Tampering with the CO Shield
®
system could result in a
hazardous condition and will void your warranty.
Removing the CO Shield module will not allow the generator to
start.