56 - INSTALLATION 91477A185/D
replace the lubrication grease.
Gas types and Countries
It is possible to identify the available gas types based on the country the appliance is to be installed
in. Refer to the heading number to identify the correct values in the “Burner and nozzle characteristics
tables".
Burner and nozzle characteristics tables
Lubrication of the gas cocks should be
performed by a specialised technician.
Gas types IT
GB
IE
FR
BE
ES PT RU
SE
DK
FI
NO
PL HU
1 Natural Gas G20
G20
20 mbar
•• ••••••
G20/25
20/25 mbar
2 Natural Gas G20
G20
25 mbar
3 Natural Gas G25.1
G25.1
25 mbar
4 Natural Gas G2.350
G2.350
13 mbar
5 LPG G30/31
G30/31
28-30/37 mbar
••••••
G30/31
30/30 mbar
••
6 LPG G30/31
G30/31
37 mbar
7 Town Gas G110
G110
8 mbar
••
1 Natural Gas G20 - 20 mbar AUX R UR-3c UR
Rated heating capacity (kW) 1.10 3.10 3.30 6.0
Nozzle diameter (1/100 mm) 76 126 130 175
Reduced flow rate (W) 400 900 1600 1800
Primary air (mm) 1 1 0.5 1
2 Natural Gas G20 - 25 mbar AUX R UR-3c UR
Rated heating capacity (kW) 1.10 3.10 3.30 6.0
Nozzle diameter (1/100 mm) 73 120 123 165
Reduced flow rate (W) 400 900 1600 1800
Primary air (mm) 1 1 1 0.5
3 Natural Gas G25.1 - 25 mbar AUX R UR-3c UR
Rated heating capacity (kW) 1.10 3.10 3.30 6.0
Nozzle diameter (1/100 mm) 76 135 140 190
Reduced flow rate (W) 400 900 1600 1800
Primary air (mm) 1 1 1 0.5
4 Natural Gas G2.350 - 13 mbar AUX R UR-3c UR
Rated heating capacity (kW) 1.10 3.10 3.30 6.0
Nozzle diameter (1/100 mm) 100 175 180 280
Reduced flow rate (W) 400 900 1600 1800
Primary air (mm) 1123