ENGLISH 100302
Power Panel
(1) Engine Switch
(2) Economy Control Switch
(3) Output Indicator Light – Remains ON during
normal operating conditions. Shuts OFF when
generator is overloaded.
(4) Overload Indicator Light – This light turns ON
when the generator is overloaded and will cut
power to the receptacles.
(5) Oil Warning Indicator Light – Check oil level
when this light turns on. Engine will not run when
indicator is lit.
(6) Parallel Receptacles – Used for parallel operation.
(7) Circuit Breaker (Push-button) – Protects the
generator against electrical overload.
CONTROLS AND FEATURES
1 82
(8) 120 Volt AC, 30 Amp Receptacle (NEMA TT-30R)
May be used to supply electrical power for the
operation of 120 Volt AC, 30 Amp, single phase
60 Hz electrical loads.
(9) 120 Volt AC, 20 Amp Duplex Receptacle
(NEMA 5-20R) – May be used to supply electrical
power for the operation of 120 Volt AC, 20 Amp,
single phase 60 Hz electrical loads.
(10) 12V DC Automotive Receptacle*
(11) Ground Terminal – Consult an electrician for local
grounding regulations.
*Warning: Do not operate a device while it is plugged into the 12V DC outlet. Prolonged exposure to engine exhaust can cause
serious injury or death. While charging a device do no place on the exhaust side of the generator. Extreme heat caused by exhaust
can damage the device, and cause a potential fire hazard.