2-1.INSTALLINGTHEUNIT
• Besuretoxtheunit’slegswithboltswheninstallingit.
• Besuretoinstalltheunitrmlytoensurethatitdoesnotfallbyanearthquakeoragust.
• Refertothegureintherightforconcretefoundation.
• Donotusethedrainsocketandthedraincapsinthecoldregion.Drainmayfreezeanditmakesthefanstop.
2-2.CONNECTINGWIRESFOROUTDOORUNIT
• Besuretousespecialcircuitsforroomairconditioner.
• Wiringworkshouldbebasedonapplicabletechnicalstandards.
• Wiringconnectionsshouldbemadefollowingthediagram.
• Screwsshouldbetightenedsotheywon’tloosen.
ELECTRICAL SPECIFICATIONS
OUTDOOR UNIT MXZ-3C24NA2 MXZ-3C30NA2 MXZ-4C36NA2
Powersupply(V,PHASE,Hz) 208/230,1,60
Max. Fuse size (time delay) (A) 25
Min. Circuit Ampacity (A) 22.1 23.1
Fan motor (F.L.A) 2.43 2.43
Compressor
(R.L.A) 12 12
(L.R.A) 13.7 13.7
Controlvoltage
Indoor unit-Remote controller : (Wireless)
Indoorunit-Outdoorunit:DC12-24V
1-3/8in.
(35mm)
5/8in.
(15 mm)
Lead wire
1)Removetheservicepanel.
2)Removetheconduitplate.
3)Attachtheconduitconnectortoconduitplatewithlocknutthensecure
it to the unit with screws.
4)ConnectgroundwirestotheTBsupport.
5)Loosen terminal screw, and connectindoor/outdoor unit connecting
wire(B)fromtheindoorunitcorrectlyontheterminalblock.Becareful
nottomakemis-wiring.Fixthewiretotheterminalblocksecurelyso
thatnopartofitscoreisappeared,andnoexternalforceisconveyed
totheconnectingsectionoftheterminalblock.
6)Firmlytightentheterminalscrewstopreventthemfromloosening.After
tightening,pullthewireslightlytoconrmthattheydonotmove.
7) Perform 5) and 6) for each indoor unit.
8) Connect power supply cord (A).
9)Closetheservicepanelsecurely.Makesurethat3-2.PIPECONNEC-
TION is completed.
Connecting order
• Connect the terminal block in
following order.
A
B
C
D
P
CONNECTINGWIRESANDCONNECTINGGROUNDWIRE
• UsesolidconductorMin.AWG14orstrandedconductorMin.AWG14.
• Usedoubleinsulatedcopperwirewith600Vinsulation.
• Usecopperconductorsonly.
* Follow local electrical code.
POWERSUPPLYCABLEANDGROUNDWIRE
• UsesolidorstrandedconductorMin.AWG12.
• Usecopperconductorsonly.
* Follow local electrical code.
WARNING:
Use the indoor/outdoor unit connecting wire that meets the Stand-
ardstoconnecttheindoorandoutdoorunitsandxthewiretothe
terminal block securely so that no external force is conveyed to the
connecting section of the terminal block. An incomplete connection
orxingofthewirecouldresultinare.
Remark:
* Adisconnectswitchshouldberequired.Checkthelocalcode.
** Use a ring tongue terminal in order to connect a ground wire to terminal.
• Connectwirestothematchingnumbersofterminals.
• Besuretoattacheachscrewtoitscorrespondentterminalwhen
securing the cord and/or the wire to the terminal block.
Terminalblock
Grounding
terminal **
208/230VAC
1phase60Hz
Grounding
terminal **
Terminalblock1
Ground
OUTDOOR UNIT
Power supply
208/230VAC
1phase2wires60Hz
Disconnect
switch *
Grounding
terminal **
Terminalblock Terminalblock
INDOOR UNIT
Terminalblock
Forfutureservicing,giveextralengthtotheconnectingwires.
Servicepanel
Screws
Power supply
Terminalblockfor
indoor/outdoorunit
A – C D
Locknut
Conduit plate
Conduit connector
Dunitisfor4C36NA2only
Dunitisfor4C36NA2only
A – C D
Fix here with
M10 bolts.
Makethesetting
depth deeper.
Makewithwider.
Anchor leg
1-1/6(30)orless
Anchor bolt length
Anchor bolt pitch
(Unit: inch (mm))
23-5/8
(600)
14-9/16
(370)
Conduit plate
2. OUTDOORUNITINSTALLATION
WG79A686H01_en.indd 4 11/24/2015 9:04:55 AM