Tripp Lite PDUMNH20 1.9kW Single-Phase Monitored PDU, 120V Outlets 8 5-15/20R, L5-20P/5-20P Adapter, 12 ft. 3.66 m Cord, 1U Rack-Mount, LX Platform Interface, TAA

Owner's Manual - Page 3

For PDUMNH20. Also, The document are for others Tripp Lite models: PDUMNH15, PDUMNH30

PDF File Manual, 24 pages, Read Online | Download pdf file

PDUMNH20 photo
Loading ...
Loading ...
Meter Select
Bank 2
Bank 1
LOAD (AMPS)
BA
3
Input Plug Adapter (Model PDUMNH20): The adapter converts a
NEMA L5-20P input plug to a NEMA 5-20P input plug.
NEMA 5-15R Outlets (Model PDUMNH15): During normal
operation, the outlets distribute AC power to connected equipment.
NEMA 5-15/20R Outlets (Models PDUMNH20 & PDUMNH30):
During normal operation, the outlets distribute AC power to connected
equipment.
Digital Load Meter (Ammeter, Models PDUMNH15 &
PDUMNH20): The total electrical current used by the PDU is displayed
on the digital meter in amperes.
Digital Load Meter (Ammeter, PDUMNH30): Displays the connected
load in amps. It can be set using the meter select switch to display the
PDU’s total connected load (all outlets-both LEDs illuminated), or the
load carried by either the upper bank (Bank 1 LED illuminated) or lower
bank (Bank 2 LED illuminated) of outlet receptacles. If you press and
hold the mode selection switch
A
for 4 seconds, the unit's IP address
will display on the meter
B
. Note: If no IP address is assigned (default),
“no address” will display, one letter at a time. If an IP address is
assigned, it will display one digit at a time, with dashes (-) representing
the dots (.) in the address.
2. Features
(
continued
)
Factory Port: The port is reserved for configuration by factory
authorized personnel only. Do not connect anything to the port.
Output Circuit Breakers (PDUMNH30): Two circuit breakers (one
per outlet bank) protect connected equipment against dangerous system
overloads. If the total load on either of the PDU’s outlet banks exceeds
20 amps, the associated circuit breaker will trip, cutting power to the
entire outlet bank. Reduce the load on the outlet bank by unplugging
some equipment; then press the circuit breaker in to restore power.
Cord Retentions Shelves (PDUMNH30, Optional): When installed on
the PDU, these shelves provide secure attachment points for connected
equipment power cords. Use the included cable ties to secure cords to
the shelf.