19
Analogue Outputs
Analogue outputs are provided on DB25 female connector(s) on the
rear panel.
The Line outputs for Red 4Pre and Red 8Pre are at fixed gain, where
0 dBFS corresponds to a signal level of +18 dBu.
Operating Level Selection
(Red 16Line only – also see: ‘Input/Output Line Level Setup’ on page 26.)
The operating level for each Line output can be switched between
+18 dBu and +24 dBu to correctly match additional studio equipment.
1 Press and hold the Output button until the level selection menu
appears on the Input Display
2 Scroll to the required channel number for individual selection
or to All for global selection
3 Click the Input Encoder to toggle between +18 dBu and +24 dBu
4 Press the Output button again to exit
Input and output operating level selection can be linked or unlinked. Refer to:
Global Settings – I/O Level on page 23 for additional information.