20
6.1 MEASURE THE RESISTANCE (TEST #3)
Use a digital Ohm meter to measure the resistance of the Heatwave® Mat/Cable and
compare it to the total Ohms in the tables in Section 4.1 for Mats or in Section 4.2 for
Cables. Record the measured resistance on the Registration Form. Documenting the
resistance at each stage of installation is required for warranty purposes. Also, measure
the resistance between each conductor and the shielding/ground wire. Both should read infinity.
Please refer to Section 7 (Commissioning) for instructions on how to measure the resistance.
6.2 INSTALL FLOOR COVERING
To install tile, apply a layer of thin-set mortar using
the ridged side of the trowel. Tile and grout the floor
using best industry practices and in accordance with
instructions provided by the tile manufacturer.
6.3 CONNECT POWER SUPPLY AND THERMOSTAT
The connection of the power supply and the thermostat
must be done by a qualified person in accordance with
the National Electrical Code (NEC) and the Canadian
Electrical Code (CEC). Connect the floor sensor to the
thermostat, take the final resistance reading and record it
on the Registration Form, see 6.5.
6.4 MEASURE THE RESISTANCE (TEST #4)
Use a digital Ohm meter to measure the resistance of the Heatwave® Mat/Cable and compare
it to the total Ohms in the tables in Section 4.1 for Mats or in Section 4.2 for Cables. Record
the measured resistance on the Registration Form. Documenting the resistance at each stage
of installation is required for warranty purposes. Also, measure the resistance between each
conductor and the shielding/ground wire. Both should read infinity. Please refer to Section 7
(Commissioning) for instructions on how to measure the resistance.
6.5 RECORD INFORMATION AND AFFIX LABELS
It is important for the home builder/owner to retain a copy and mail in the
warranty certificate immediately after installing the system (Heatwave® Mat
or Cable and Thermostat). Failure to do so could void the manufacturers
warranty. The warranty is subject to the guarantee conditions listed on
the warranty certificate. Keep a copy of the Registration Form for future
reference. Place the included label “Electric Shock or Fire Hazard” on the
inside of the electrical power distribution panel.
6.6 ENJOY THE COMFORT OF HEATWAVE
The Heatwave® Heating System is now ready to use. Increase the floor temperature gradually
and adjust it until it reaches a comfortable level depending on the type of room and personal
preferences.
Mark the appropriate circuit breaker reference label indicating which branch
circuit supplies the power to each electric heating cable.