Venting Requirements
DO
Have the venting system go vertically from the
range hood to the roof if possible.
Have 24"-30" distance between the cooktop and
the range hood. 27" is recommended.
Use uniformed duct of 6" round duct or 3-1/4 x 10”
rectangular duct or larger.
Use metal vent only. Rigid metal vent is
recommended. Semi-rigid aluminum vent is also
acceptable for easy connection.
Make sure there is a minimum of 24" of straight
vent between the elbows if more than 1 elbow is
used.
Use minimal numbers of elbows and the
shortest route for the venting system for a better
performance.
Use silver tap or duct tap to seal all joints in the
venting system.
Use caulking silicone to seal exterior wall or roof
opening around the cap.
Always keep the duct clean to ensure proper airflow.
DO NOT
End the venting system in an enclosed area indoors.
Use plastic vent.
Use no more than three 90° elbows.
Install 2 elbows together.
Install the range hood outside of the recommended
height.
Reduce the duct size below the recommended size.
Venting System Setup:
For RH-C06 models: This range hood is 6” top
venting through the roof or wall.
For RH-R06 models: This range hood is 3-1/4 x 10”
top or rear venting through the roof or wall.
INSTALLATION PREPARATIONS
Cabinet Cabinet
Side
Wall
Cap
Range Hood Range Hood
Stove Top
Stove Top
Roof Cap
Rear Venting Wall Exhaust
Top Venting Roof Exhaust
Cabinet
Side
Wall
Cap
Range Hood
Stove Top
Top Venting Wall Exhaust
* For RH-C06 & RH-R06 Models
* For RH-R06 Models Only