Renogy 12V 30A DC TO DC CHARGER WITH MPPT On-Board Battery Charger

User Manual - Page 16

For 12V 30A DC TO DC CHARGER WITH MPPT.

PDF File Manual, 24 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
15
LED Indicators
Operation
Color
Status
Description
Red
ON Bulk charge (MPPT)
Slow Flashing Boost charge
Color Status Description
Color Status Description
Color Status Description
Solar Charging Indicator
Single Flashing Float charge
Fast Flashing Equalizing charge
Double Flashing Current-limit charge
OFF Not charging
Red
ON Alternator is charging the service battery
Slow Flashing PV is charging the starting battery
Alternator/Charging Indicator
OFF Not charging
Red
Yellow
Green ON Battery Full
ON Battery voltage normal
Service Battery Indicator
ON Battery undervoltage
Slow Flashing Battery over discharged
Fast Flashing Battery over voltage/ over temperature
Red
Yellow
White
Blue
Green ON SLA (Default)
ON GEL
Battery Type Indicator
ON FLD
ON LI
ON User
NOTE
1. Red to Yellow: When the voltage reaches 12.2V under voltage recovery
2. Yellow to Red: When the voltage drops to 12.0V under voltage warning
3. Yellow to Green: A. When it reaches constant voltage charging state, the charging current is
smaller than 3A, lasts for 30 seconds; B. When the charging current is higher than 3A, it keeps
charging until it reaches constant voltage state and the current drops below 3A, lasts 30 seconds.
The Charging Indicator may change under the following conditions:
User mode is an extra feature accessed via App or Monitoring Screen; Future
Development
NOTE