Waldorf RNL8510GC 800 Series 750mm Gas Range Convection Oven Low Back Version

Installation Operation Manual - Page 11

For RNL8510GC.

PDF File Manual, 32 pages, Read Online | Download pdf file

RNL8510GC photo
Loading ...
Loading ...
Loading ...
9
NOTE:
It is most important that this appliance is installed correctly and that operation is correct
before use. Installation shall comply with local gas, electrical and health and safety
requirements.
This appliance shall be installed with sufficient ventilation to prevent occurrence of
unacceptable concentrations of health harmful substances in room, appliance is installed
in.
Waldorf Gas Range Convection Ovens are designed to provide years of satisfactory service, and correct
installation is essential to achieve the best performance, efficiency and trouble-free operation. This
appliance must be installed in accordance with National installation codes and in addition, in accordance
with relevant National / Local codes covering gas, electrical and fire safety.
Australia / New Zealand: - AS/NZS5601 - Gas Installations.
- AS/NZS 3000 - Wiring Rules.
United Kingdom: - Gas Safety (Installation & Use) Regulations 1998.
- BS 6173 - Installation of Catering Appliances.
- BS 5440 1 & 2 - Installation Flueing & Ventilation.
- BS 7671 - Requirements for Electrical Installation.
Ireland: - IS 820- Non - Domestic Gas Installations.
Installation must be carried out by authorised persons only. Failure to install equipment to
relevant codes and manufacturers specifications shown in this section will void the
warranty.
Components having adjustments protected (e.g. paint sealed) by manufacturer are only
to be adjusted by an authorised service agent. They are not to be adjusted by the installation
person.
Remove all packaging and transit protection from appliance including all protective plastic coating
from exterior stainless steel panels.
Check equipment and parts for damage. Report any damage immediately to carrier and distributor.
Report any deficiencies to distributor who supplied appliance.
Check that available gas and electrical supply is correct to as shown on rating plate located on front
right hand corner of bottom sill.
1. Installation must allow for a sufficient flow of fresh air for the combustion air supply.
2. Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3. Never directly connect a ventilation system to appliance flue outlet.
4. Position appliance in its approximate working position.
5. All air for burner combustion is supplied from beneath the appliance. Legs must always be fitted and
no obstructions placed under or around base of appliance, as obstructions will cause incorrect
operation and / or failure of the appliance.
NOTE: Do not obstruct or block the appliances flue. Never directly connect a ventilation system to
the appliance flue outlet.
Combustion Air Requirements:
RN8510GC RN8610GC RN8810GC
Natural Gas 37 m
3
/hr 51 m
3
/hr 66 m
3
/hr
LPG / Butane 38 m
3
/hr 53 m
3
/hr 68 m
3
/hr
Town Gas 37 m
3
/hr 51 m
3
/hr 66 m
3
/hr
Loading ...
Loading ...
Loading ...