PROBLEM POSSIBLE CAUSE SOLUTION
Workpiece contact does not depress
fully - tool does not operate
Low nails
Work-contacting element is jammed
Remove battery and replenish nails
Remove battery and clear jam
Tool operates properly, but nails do not
drive fully
Air pressure is too low
Depth of drive isn’t deep enough
Nail is too long for wood hardness
Trigger released too soon
Battery pairing is unsuitable
Increase power
Adjust depth of drive
Use nail length that is appropriate for
wood
Hold trigger until fastener is driven
Use a 3Ah battery or higher
Tool operates properly, but nails are
driven too deep
Air pressure is too high
Depth of drive is too deep
Decrease drive power
Adjust depth of drive
Tool jams frequently Incorrect nails
Damaged nails
Loose magazine
Dirty magazine
Verify that nails are the correct size
Replace nails
Tighten screws
Clean magazine
Tool stops and LED flashes rapidly Battery is low or has no charge
Trigger released too early
Recharge battery
Remove battery and reinstall.
Tool has charged battery and LED is
slowly flashing or LED does not turn
off after approximately ten seconds of
non-use
Tool has malfunctioned Take tool to nearest authorized repair
center
Tool will not drive a fastener or cycles
without driving a fastener
Driving mechanism is dirty Clean the nail channel as described in
the Maintenance section of the manual
NOTE: ILLUSTRATIONS START ON PAGE 12
AFTER FRENCH AND SPANISH LANGUAGE SECTIONS.
TROUBLESHOOTING
MAINTENANCE
WARNING:
When servicing, use only identical replacement parts.
Use of any other parts could create a hazard or cause
product damage.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
CLEANING THE NAIL CHANNEL
See Figure 13, page 13.
If the tool will not drive a nail, or cycles without driving a nail,
glue residue from the nail strip may need to be cleaned from
the area around the driving mechanism.
Remove the battery pack.
Remove nails from the tool.
Open the jam release latch and the magazine.
Use a small amount of air tool oil on a clean cloth or cotton
swab to wipe down the nail channel, removing all traces
of glue.