PLANNING GUIDE
MODULAR COOKTOPS
CI392DTT CI604DTT CIDTT CI905DTT CID CI392D
CITDX CIT392DX1 | CD13D

© FISHER & PAYKEL LIMITED 202 PAGE 29000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
CI92DTT CI604DTT CIDTT CI905DTT CID CI92D CITDX CIT92DX1 | CD1DPLANNING GUIDE | MODULAR COOKTOPS
This comprehensive planning guide provides you with the framework and tools to achieve your desired design outcome with Fisher & Paykel appliances. In this guide, you will
find a range of conceptual, detailed, and dimensional product information to bring your ideas to life and create spaces that truly reflect your vision.
CONCEPT DESIGN PAGE DEVELOPED AND DETAILED DESIGN PAGE DEVELOPED AND DETAILED DESIGN PAGE
Specification Guide 3
System Overview 4
Primary Modules 6
Auxiliary Modules 7
Data Sheets 8
Primary Induction Cooktop, 9cm 9
Primary Induction Cooktop, 60cm 10
Primary Induction Cooktop, 76cm 11
Primary Induction Cooktop, 90cm 12
Auxiliary Induction Cooktop, 0cm 1
Auxiliary Teppanyaki Cooktop, 0cm 14
Auxiliary Induction Cooktop, 9cm 15
Auxiliary Teppanyaki Cooktop, 9cm 16
Auxiliary Ventilation Components 17
Auxiliary Ventilation Mainbox 18
Auxiliary Ventilation Blowerbox 19
Horizontal Elbow, 90
Vertical Elbow, 90
Duct Adaptor, 90150mm Diameter 22
Duct Adaptor, 150mm Diameter 2
Connector 24
Straight Duct 25
Horizontal Elbow, Steel 26
Recirculation Kit 27
Product Decisions 29
Pairing Guide 0
Modular System Capabilities 1
Modular Ventilation Capabilites 2
Ventilation Choice
Planning Considerations 34
Installation Overview 5
Installation Planning 6
Typical Configurations with Modular Ventilation 7
Typical Configurations with Overhead Ventilation 8
Benchtop Details 9
Clamping Locations 40
Cooktop Ventilation 41
Modular Ventilation Cabinetry Overview 42
Modular Ventilation Overview 4
Typical Ducting Dimensions 44
Typical Cabinetry Configurations 45
Blowerbox Cabinetry 46
Electrical Services 47
Modular Connections 49
CONTENTS

© FISHER & PAYKEL LIMITED 202 PAGE 9000269B PLANNING GUIDE MODULAR COOKTOPS - VERSION B - OCTOBER 202
SPECIFICATION GUIDE

© FISHER & PAYKEL LIMITED 202 PAGE 49000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
SPECIFICATION GUIDE | MODULAR COOKTOPS
OVERVIEW
Create the ultimate culinary solution with our Series 9 and 11
modular cooktops. Using the dierent induction, teppan and
ventilation modules, you can customise the cooking area at the
scale and format best suited to architectural plan and user
needs. Fusing precise induction technology with innovative
design, these modules are crafted to seamlessly work together
for perfect results
FEATURES
1 Tailor the cooking space by pairing primary induction
cooktop modules with complementary auxiliary cooktops,
downdraft ventilation and teppan modules.
2 Control the complete modular suite from the primary cooktop
using a large intuitive touchscreen.
3 Each module is designed to fit flush or raised with the
countertop for complete design freedom.
4 Choose from a Minimal-style, sleek black glass or subtle grey
glass finish to suit your kitchen design.
5 SmartHQ™ app connectivity to monitor cook status and
product.
6 Wireless Temperature Sensor precisely monitors and controls
cooking in real time, for complete control.*
7 Poach, Sous Vide and other Cook by Method functions are
available on product, when using the Wireless Temperature
Sensor.
* Selected models only.
PRODUCT OVERVIEW
PRIMARY MODULAR INDUCTION COOKTOPS
With touchscreen user interface
CI392DTTB1 (Black), CI392DTTG1 (Grey)
Primary Modular Induction Cooktop, 39cm, 2 Zones with
SmartZone
CI604DTTB1 (Black), CI604DTTG1 (Grey)
Primary Modular Induction Cooktop, 60cm, 4 Zones with
SmartZone
CI764DTTB1 (Black), CI764DTTG1 (Grey)
Primary Modular Induction Cooktop, 76cm, 4 Zones with
SmartZone
CI905DTTB1 (Black), CI905DTTG1 (Grey)
Primary Modular Induction Cooktop, 90cm, 5 Zones with
SmartZone
AUXILIARY MODULAR COOKTOPS
No user interface. Controlled via paired primary cooktop.
CI302DB1 (Black), CI302DG1 (Grey)
Auxiliary Modular Induction Cooktop, 30cm, 2 Zones with
SmartZone
CI392DB1 (Black), CI392DG1 (Grey)
Auxiliary Modular Induction Cooktop, 39cm, 2 Zones with
SmartZone
CIT302DX1
Auxiliary Modular Teppanyaki Cooktop, 30cm, 2 Zones
CIT392DX1
Auxiliary Modular Teppanyaki Cooktop, 39cm, 2 Zones
AUXILIARY MODULAR VENTILATION
No user interface. Controlled via paired primary cooktop.
CD13DB1 (Black), CD13DG1 (Grey)
Auxiliary Modular Ventilation, 13cm, Duct Out

© FISHER & PAYKEL LIMITED 202 PAGE 59000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
PRODUCT OVERVIEW CONTINUED
ACCESSORIES
WTSC1
Wireless Temperature Sensor (1x included per Primary Modular
Induction Cooktop. Also available to purchase separately).
E90H30X7
Horizontal Elbow, 90°, 300x70mm
E90V30X7
Vertical Elbow, 90°, 300x70mm
DA90D30X7D15
Duct Adaptor, 90°, 150mm Diameter, 300x70mm
DA30X7D15
Duct Adaptor, 150mm Diameter, 300x70mm
D100X30X7
Duct, 1m, 300x70mm
C30X7
Connector, 300x70mm
E90H30X7S
Horizontal Elbow, 90°, 300x70mm, Steel
KRCID834
Recirculation Kit
OAB222X89
Outlet Adaptor, 222x89, Recirculation
SPECIFICATION GUIDE | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 69000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 69000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
PRIMARY MODULES
PRIMARY MODULAR INDUCTION COOKTOP, 39CM,
2 ZONES WITH SMARTZONE
Model no:
CI92DTTB1 Black
CI92DTTG1 Grey
Dimensions
W x D x H
Product
85 x 50 x 62
Glass
85 x 50 x 6
Cutout, proud
47 x 507
Cutout, flush
47 x 509
Recess, flush
89 x 54 x 6.5
Power Requirements
Supply
220-240 V, 50 Hz / 60 Hz
Service
16 A
Connection
Power cord, stripped ends, 1 N
Power Cable
1700 mm
Weight 8 kg
PRIMARY MODULAR INDUCTION COOKTOP, 60CM,
4 ZONES WITH SMARTZONE
Model no:
CI604DTTB1 Black
CI604DTTG1 Grey
Dimensions W x D x H
Product
600 x 50 x 62
Glass 600 x 50 x 6
Cutout, proud 562 x 507
Cutout, flush 562 x 509
Recess, flush 604 x 54 x 6.5
Power Requirements
Supply
220-240 V, 50 Hz / 60 Hz
Service
2 A
Connection
Terminal block, 1 N or 2 N
Power Cable
not supplied
Weight
14 kg
PRIMARY MODULAR INDUCTION COOKTOP, 76CM,
4 ZONES WITH SMARTZONE
Model no:
CI764DTTB1 Black
CI764DTTG1 Grey
Dimensions
W x D x H
Product
760 x 50 x 62
Glass
760 x 50 x 6
Cutout, proud
722 x 507
Cutout, flush
722 x 509
Recess, flush
764 x 54 x 6.5
Power Requirements
Supply
220-240 V, 50 Hz / 60 Hz
Service
2 A
Connection
Terminal block, 1 N or 2 N
Power Cable
not supplied
Weight
16 kg
PRIMARY MODULAR INDUCTION COOKTOP, 90CM,
5 ZONES WITH SMARTZONE
Model no:
CI905DTTB1 Black
CI905DTTG1 Grey
Dimensions
W x D x H
Product
900 x 50 x 62
Glass
900 x 50 x 6
Cutout, proud
862 x 507
Cutout, flush
862 x 509
Recess, flush
904 x 54 x 6.5
Power Requirements
Supply
220-240 V, 50 Hz / 60 Hz
Service
48 A
Connection
Terminal block, 1 N or N
Power Cable
not supplied
Weight
20 kg
PRODUCT SPECIFICATIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 79000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
AUXILIARY MODULES
AUXILIARY MODULAR INDUCTION COOKTOP,
30CM, 2 ZONES WITH SMARTZONE
Model no:
CI02DB1 Black
CI02DG1 Grey
Dimensions
W x D x H
Product
00 x 50 x 62
Glass
00 x 50 x 6
Cutout, proud
262 x 507
Cutout, flush
262 x 509
Recess, flush
04 x 54 x 6.5
Power Requirements
Supply
220-240 V, 50 Hz / 60 Hz
Service
16 A
Connection
Power cord, stripped ends, 1 N
Power Cable
1700 mm
Weight
7 kg
AUXILIARY MODULAR INDUCTION COOKTOP,
39CM, 2 ZONES WITH SMARTZONE
Model no:
CI92DB1 Black
CI92DG1 Grey
Dimensions
W x D x H
Product
85 x 50 x 62
Glass
85 x 50 x 6
Cutout, proud
47 x 507
Cutout, flush
47 x 509
Recess, flush
89 x 54 x 6.5
Power Requirements
Supply
220-240 V, 50 Hz / 60 Hz
Service
16 A
Connection
Power cord, stripped ends, 1 N
Power Cable
1700 mm
Weight
8 kg
AUXILIARY MODULAR VENTILATION,
13CM
Model no:
CD1DB1 Black
CD1DG1 Grey
Dimensions
W x D x H
Product
10 x 50 x 186
Glass
10 x 50 x 6
Cutout, proud**
98 x 507
Cutout, flush**
98 x 509
Recess, flush**
14 x 54 x 6.5
Power Requirements
Supply
220-240V, 50Hz
Service
5A
Connection
Power cord, plug
Power Cable
000 mm
Weight
kg
** Must be installed in combined cutout with cooktop
AUXILIARY MODULAR TEPPANYAKI COOKTOP,
39CM, 2 ZONES
Model no:
CI92DX1
Dimensions
W x D x H
Product
85 x 50 x 74
Plate
85 x 50 x 6
Cutout, proud
47 x 507
Cutout, flush
47 x 509
Recess, flush
89 x 54 x 6.5
Power Requirements
Supply
220-240 V, 50 Hz / 60 Hz
Service
12 A
Connection
Power cord, stripped ends, 1 N
Power Cable
1700 mm
Weight
15 kg
AUXILIARY MODULAR TEPPANYAKI COOKTOP,
30CM, 2 ZONES
Model no:
CIT02DX1
Dimensions
W x D x H
Product
00 x 50 x 74
Plate
00 x 50 x 6
Cutout, proud
262 x 507
Cutout, flush
262 x 509
Recess, flush
04 x 54 x 6.5
Power Requirements
Supply
220-240 V, 50 Hz / 60 Hz
Service
12 A
Connection
Power cord, stripped ends, 1 N
Power Cable
1700 mm
Weight
12 kg
PRODUCT SPECIFICATIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 89000269B PLANNING GUIDE MODULAR COOKTOPS - VERSION B - OCTOBER 202
DATA SHEETS

© FISHER & PAYKEL LIMITED 202 PAGE 99000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 99000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
CI92DTTB1, CI92DTTG1
0 100 200 400
millimetres
CLEARANCE: REAR
TOP VIEW
m
l
k
e
CLEARANCE: SIDE
f
j k
h
CLEARANCE: BELOW COOKTOP
PROFILE VIEW
c
530
DATUM:
TOP OF COOK SURFACE
A
d
i
i
g
CLEARANCE: BELOW COOKTOP
FRONT VIEW
b
385
POWER OUTLET
CLEARANCE: OVERHEAD CABINET
NOT DIRECTLY ABOVE
CLEARANCE: RANGEHOOD,
OVERHEAD CABINET DIRECTLY ABOVE
n o
P
Model no:
Primary Modular Induction Cooktop, 39cm, 2 Zones with SmartZone, Black - CI392DTTB1,
Primary Modular Induction Cooktop, 39cm, 2 Zones with SmartZone, Grey - CI392DTTG1
Product Dimensions
mm
a Overall height of cooktop
62
B Overall width of cooktop
85
c Overall depth of cooktop
50
d Height of cooktop glass (includes flange and tape)
6
e Corner radius of glass
2
f Height of chassis
56
G Width of chassis
4
h Depth of chassis
504
i Width from side edges of cooktop to chassis
25.5
j Depth from front edge of cooktop to chassis
1.5
k Depth from back edge of cooktop to chassis
12.5
Product Clearances
mm
l Minimum clearance from side edges of cutout to nearest combustible surface
29
m Minimum clearance from rear edge of cutout to nearest combustible surface
21
n Minimum clearance from cook surface to rangehood or overhead cabinet
610
o Minimum clearance from cook surface to overhead cabinet not directly above
cooktop
450
P Maximum depth of overhead cabinetry
0
Minimum ventilation gap between bottom of benchtop and top of cabinetry
fronts (not shown)
4
Minimum clearance from cook surface to top of any appliances, companion
product or obstruction below cooktop
72
NOTE: The oven installed below the cooktop MUST have a cooling fan. It is important that the induction cooktop
receives adequate air supply. For ventilation requirements please refer to the installation manual.
Cutout Dimensions*
Proud mm
Flush mm
Overall width of cutout
47
47
Overall depth of cutout
507
509
Overall width of recess
-
89
Overall depth of recess
-
54
Overall height of recess
-
6.5
Recess corner radius
-
4
*Note cutout position is centred to the cooktop.
DATA SHEETS | MODULAR COOKTOPSDATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 109000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 109000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
CI604DTTB1, CI604DTTG1
0 100 200 400
millimetres
CLEARANCE: REAR
TOP VIEW
m
l
k
e
CLEARANCE: SIDE
b
600
A
d
i
i
CLEARANCE: BELOW COOKTOP
g
FRONT VIEW
DATUM:
TOP OF COOK SURFACE
f
j k
h
CLEARANCE: BELOW COOKTOP
PROFILE VIEW
c
530
POWER OUTLET
CLEARANCE: OVERHEAD CABINET
NOT DIRECTLY ABOVE
CLEARANCE: RANGEHOOD,
OVERHEAD CABINET DIRECTLY ABOVE
n o
P
Model no:
Primary Modular Induction Cooktop, 60cm, 4 Zones with SmartZone, Black - CI604DTTB1,
Primary Modular Induction Cooktop, 60cm, 4 Zones with SmartZone, Grey - CI604DTTG1
Product Dimensions
mm
a Overall height of cooktop
62
B Overall width of cooktop
600
c Overall depth of cooktop
50
d Height of cooktop glass (includes flange and tape)
6
e Corner radius of glass
2
f Height of chassis
56
G Width of chassis
554
h Depth of chassis
504
i Width from side edges of cooktop to chassis
2
j Depth from front edge of cooktop to chassis
1.5
k Depth from back edge of cooktop to chassis
12.5
Product Clearances
mm
l Minimum clearance from side edges of cutout to nearest combustible surface
29
m Minimum clearance from rear edge of cutout to nearest combustible surface
21
n Minimum clearance from cook surface to rangehood or overhead cabinet
610
o Minimum clearance from cook surface to overhead cabinet not directly above
cooktop
450
P Maximum depth of overhead cabinetry
0
Minimum ventilation gap between bottom of benchtop and top of cabinetry
fronts (not shown)
4
Minimum clearance from cook surface to top of any appliances, companion
product or obstruction below cooktop
72
NOTE: The oven installed below the cooktop MUST have a cooling fan. It is important that the induction cooktop
receives adequate air supply. For ventilation requirements please refer to the installation manual.
Cutout Dimensions*
Proud mm
Flush mm
Overall width of cutout
562
562
Overall depth of cutout
507
509
Overall width of recess
-
604
Overall depth of recess
-
54
Overall height of recess
-
6.5
Recess corner radius
-
4
*Note cutout position is centred to the cooktop.
DATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 119000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 119000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
CI764DTTB1, CI764DTTG1
0 100 200 400
millimetres
A
f
d
i
i
g
j k
h
CLEARANCE: BELOW COOKTOP
CLEARANCE: BELOW COOKTOP
PROFILE VIEWFRONT VIEW
b
760
CLEARANCE: REAR
TOP VIEW
CLEARANCE: SIDE
m
l
k
e
DATUM:
TOP OF COOK SURFACE
c
530
POWER OUTLET
CLEARANCE: OVERHEAD CABINET
NOT DIRECTLY ABOVE
CLEARANCE: RANGEHOOD,
OVERHEAD CABINET DIRECTLY ABOVE
n o
P
Model no:
Primary Modular Induction Cooktop, 76cm, 4 Zones with SmartZone, Black - CI764DTTB1,
Primary Modular Induction Cooktop, 76cm, 4 Zones with SmartZone, Grey - CI764DTTG1
Product Dimensions
mm
a Overall height of cooktop
62
B Overall width of cooktop
760
c Overall depth of cooktop
50
d Height of cooktop glass (includes flange and tape)
6
e Corner radius of glass
2
f Height of chassis
56
G Width of chassis
714
h Depth of chassis
504
i Width from side edges of cooktop to chassis
2
j Depth from front edge of cooktop to chassis
1.5
k Depth from back edge of cooktop to chassis
12.5
Product Clearances
mm
l Minimum clearance from side edges of cutout to nearest combustible surface
29
m Minimum clearance from rear edge of cutout to nearest combustible surface
21
n Minimum clearance from cook surface to rangehood or overhead cabinet
610
o Minimum clearance from cook surface to overhead cabinet not directly above
cooktop
450
P Maximum depth of overhead cabinetry
0
Minimum ventilation gap between bottom of benchtop and top of cabinetry
fronts (not shown)
4
Minimum clearance from cook surface to top of any appliances, companion
product or obstruction below cooktop
72
NOTE: The oven installed below the cooktop MUST have a cooling fan. It is important that the induction cooktop
receives adequate air supply. For ventilation requirements please refer to the installation manual.
Cutout Dimensions*
Proud mm
Flush mm
Overall width of cutout
722
722
Overall depth of cutout
507
509
Overall width of recess
-
764
Overall depth of recess
-
54
Overall height of recess
-
6.5
Recess corner radius
-
4
*Note cutout position is centred to the cooktop.
DATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 129000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 129000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
0 100 200 400
millimetres
CLEARANCE: SIDE
A
f
d
i
i
g
j
k
h
DATUM:
TOP OF COOK SURFACE
CLEARANCE: REAR
CLEARANCE: BELOW COOKTOP
CLEARANCE: BELOW COOKTOP
TOP VIEW
PROFILE VIEWFRONT VIEW
b
900
m
l
k
c
530
e
POWER OUTLET
CLEARANCE: OVERHEAD CABINET
NOT DIRECTLY ABOVE
CLEARANCE: RANGEHOOD,
OVERHEAD CABINET DIRECTLY ABOVE
n o
P
CI905DTTB1, CI905DTTG1
Model no:
Primary Modular Induction Cooktop, 90cm, 5 Zones with SmartZone, Black - CI905DTTB1
Primary Modular Induction Cooktop, 90cm, 5 Zones with SmartZone, Grey - CI905DTTG1
Product Dimensions
mm
a Overall height of cooktop
62
B Overall width of cooktop
900
c Overall depth of cooktop
50
d Height of cooktop glass (includes flange and tape)
6
e Corner radius of glass
2
f Height of chassis
56
G Width of chassis
854
h Depth of chassis
504
i Width from side edges of cooktop to chassis
2
j Depth from front edge of cooktop to chassis
1.5
k Depth from back edge of cooktop to chassis
12.5
Product Clearances
mm
l Minimum clearance from side edges of cutout to nearest combustible surface
29
m Minimum clearance from rear edge of cutout to nearest combustible surface
21
n Minimum clearance from cook surface to rangehood or overhead cabinet
610
o Minimum clearance from cook surface to overhead cabinet not directly above
cooktop
450
P Maximum depth of overhead cabinetry
0
Minimum ventilation gap between bottom of benchtop and top of cabinetry
fronts (not shown)
4
Minimum clearance from cook surface to top of any appliances, companion
product or obstruction below cooktop
72
NOTE: The oven installed below the cooktop MUST have a cooling fan. It is important that the induction cooktop
receives adequate air supply. For ventilation requirements please refer to the installation manual.
Cutout Dimensions*
Proud mm
Flush mm
Overall width of cutout
862
862
Overall depth of cutout
507
509
Overall width of recess
-
904
Overall depth of recess
-
54
Overall height of recess
-
6.5
Recess corner radius
-
4
*Note cutout position is centred to the cooktop.
DATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 19000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 19000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
CI02DB1, CI02DG1
0 100 200 400
millimetres
CLEARANCE: REAR
TOP VIEW
CLEARANCE: SIDE
m
l
e
k
A
d
i
i
g
CLEARANCE: BELOW COOKTOP
FRONT VIEW
b
300
f
j k
h
CLEARANCE: BELOW COOKTOP
PROFILE VIEW
c
530
DATUM:
TOP OF COOK SURFACE
POWER OUTLET
CLEARANCE: OVERHEAD CABINET
NOT DIRECTLY ABOVE
CLEARANCE: RANGEHOOD,
OVERHEAD CABINET DIRECTLY ABOVE
n o
P
Model no:
Auxiliary Modular Induction Cooktop, 30cm, 2 Zones with SmartZone, Black - CI302DB1
Auxiliary Modular Induction Cooktop, 30cm, 2 Zones with SmartZone, Grey - CI302DG1
Product Dimensions
mm
a Overall height of cooktop
62
B Overall width of cooktop
00
c Overall depth of cooktop
50
d Height of cooktop glass (includes flange and tape)
6
e Corner radius of glass
2
f Height of chassis
56
G Width of chassis
254
h Depth of chassis
504
i Width from side edges of cooktop to chassis
2
j Depth from front edge of cooktop to chassis
1.5
k Depth from back edge of cooktop to chassis
12.5
Product Clearances
mm
l Minimum clearance from side edges of cutout to nearest combustible surface
29
m Minimum clearance from rear edge of cutout to nearest combustible surface
21
n Minimum clearance from cook surface to rangehood or overhead cabinet
610
o Minimum clearance from cook surface to overhead cabinet not directly above
cooktop
450
P Maximum depth of overhead cabinetry
0
Minimum ventilation gap between bottom of benchtop and top of cabinetry
fronts (not shown)
4
Minimum clearance from cook surface to top of any appliances, companion
product or obstruction below cooktop
72
NOTE: The oven installed below the cooktop MUST have a cooling fan. It is important that the induction cooktop
receives adequate air supply. For ventilation requirements please refer to the installation manual.
Cutout Dimensions*
Proud mm
Flush mm
Overall width of cutout
262
262
Overall depth of cutout
507
509
Overall width of recess
-
04
Overall depth of recess
-
54
Overall height of recess
-
6.5
Recess corner radius
-
4
*Note cutout position is centred to the cooktop.
DATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 149000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 149000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
CIT02DX1
0 100 200 400
millimetres
FRONT VIEW
TOP VIEW
f
j k
h
CLEARANCE: BELOW COOKTOP
PROFILE VIEW
c
530
DATUM:
TOP OF COOK SURFACE
CLEARANCE: REAR
TOP VIEW
CLEARANCE: SIDE
e
m
l
k
b
300
A
d
i
i
CLEARANCE: BELOW COOKTOP
g
POWER OUTLET
CLEARANCE: OVERHEAD CABINET
NOT DIRECTLY ABOVE
CLEARANCE: RANGEHOOD,
OVERHEAD CABINET DIRECTLY ABOVE
n o
P
Model no:
Auxiliary Modular Teppanyaki Cooktop 30cm, 2 Zones - CIT302DX1
Product Dimensions
mm
a Overall height of cooktop
74
B Overall width of cooktop
00
c Overall depth of cooktop
50
d Height of stainless steel cook plate (includes flange and tape)
6
e Corner radius of cooktop surface
2
f Height of chassis
68
G Width of chassis
251
h Depth of chassis
504
i Width from side edges of cooktop to chassis
24.5
j Depth from front edge of cooktop to chassis
1.5
k Depth from back edge of cooktop to chassis
12.5
Product Clearances
mm
l Minimum clearance from side edges of cutout to nearest combustible surface
29
m Minimum clearance from rear edge of cutout to nearest combustible surface
21
n Minimum clearance from cook surface to rangehood or overhead cabinet
610
o Minimum clearance from cook surface to overhead cabinet not directly above
cooktop
450
P Maximum depth of overhead cabinetry
0
Minimum ventilation gap between bottom of benchtop and top of cabinetry
fronts (not shown)
4
Minimum clearance from cook surface to top of any appliances, companion
product or obstruction below cooktop
86
NOTE: The oven installed below the cooktop MUST have a cooling fan. It is important that the induction cooktop
receives adequate air supply. For ventilation requirements please refer to the installation manual.
Cutout Dimensions*
Proud mm
Flush mm
Overall width of cutout
262
262
Overall depth of cutout
507
509
Overall width of recess
-
04
Overall depth of recess
-
54
Overall height of recess
-
6.5
Recess corner radius
-
4
*Note cutout position is centred to the cooktop.
DATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 159000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 159000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
CI92DB1, CI92DG1
0 100 200 400
millimetres
CLEARANCE: REAR
TOP VIEW
m
l
k
e
CLEARANCE: SIDE
f
j k
h
CLEARANCE: BELOW COOKTOP
PROFILE VIEW
c
530
DATUM:
TOP OF COOK SURFACE
A
d
i
i
g
CLEARANCE: BELOW COOKTOP
FRONT VIEW
b
385
POWER OUTLET
CLEARANCE: OVERHEAD CABINET
NOT DIRECTLY ABOVE
CLEARANCE: RANGEHOOD,
OVERHEAD CABINET DIRECTLY ABOVE
n o
P
Model no:
Auxiliary Modular Induction Cooktop, 39cm, 2 Zones with SmartZone, Black - CI392DB1
Auxiliary Modular Induction Cooktop, 39cm, 2 Zones with SmartZone, Grey - CI392DG1
Product Dimensions
mm
a Overall height of cooktop
62
B Overall width of cooktop
85
c Overall depth of cooktop
50
d Height of cooktop glass (includes flange and tape)
6
e Corner radius of glass
2
f Height of chassis
56
G Width of chassis
4
h Depth of chassis
504
i Width from side edges of cooktop to chassis
25.5
j Depth from front edge of cooktop to chassis
1.5
k Depth from back edge of cooktop to chassis
12.5
Product Clearances
mm
l Minimum clearance from side edges of cutout to nearest combustible surface
29
m Minimum clearance from rear edge of cutout to nearest combustible surface
21
n Minimum clearance from cook surface to rangehood or overhead cabinet
610
o Minimum clearance from cook surface to overhead cabinet not directly above
cooktop
450
P Maximum depth of overhead cabinetry
0
Minimum ventilation gap between bottom of benchtop and top of cabinetry
fronts (not shown)
4
Minimum clearance from cook surface to top of any appliances, companion
product or obstruction below cooktop
72
NOTE: The oven installed below the cooktop MUST have a cooling fan. It is important that the induction cooktop
receives adequate air supply. For ventilation requirements please refer to the installation manual.
Cutout Dimensions*
Proud mm
Flush mm
Overall width of cutout
47
47
Overall depth of cutout
507
509
Overall width of recess
-
89
Overall depth of recess
-
54
Overall height of recess
-
6.5
Recess corner radius
-
4
*Note cutout position is centred to the cooktop.
DATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 169000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 169000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
CIT92DBX1
Model no:
Auxiliary Modular Teppanyaki Cooktop 39cm, 2 Zones - CIT392DBX1
Product Dimensions
mm
a Overall height of cooktop
74
B Overall width of cooktop
85
c Overall depth of cooktop
50
d Height of stainless steel cook plate (includes flange and tape)
6
e Radius of the corner
2
f Height of chassis
68
G Width of chassis
6
h Depth of chassis
504
i Width from side edges of cooktop to chassis
24.5
j Depth from front edge of cooktop to chassis
1.5
k Depth from back edge of cooktop to chassis
12.5
Product Clearances
mm
l Minimum clearance from side edges of cutout to nearest combustible surface
29
m Minimum clearance from rear edge of cutout to nearest combustible surface
21
n Minimum clearance from cook surface to rangehood or overhead cabinet
610
o Minimum clearance from cook surface to overhead cabinet not directly above
cooktop
450
P Maximum depth of overhead cabinetry
0
Minimum ventilation gap between bottom of benchtop and top of cabinetry
fronts (not shown)
4
Minimum clearance from cook surface to top of any appliances, companion
product or obstruction below cooktop
86
NOTE: The oven installed below the cooktop MUST have a cooling fan. It is important that the teppanyaki
cooktop receives adequate air supply. For ventilation requirements please refer to page
Cutout Dimensions*
Proud mm
Flush mm
Overall width of cutout
47
47
Overall depth of cutout
507
509
Overall width of recess
-
89
Overall depth of recess
-
54
Overall height of recess
-
6.5
Recess corner radius
-
4
*Note cutout position is centred to the cooktop.
0 100 200 400
millimetres
CLEARANCE: REAR
CLEARANCE: SIDE
CLEARANCE: BELOW COOKTOP
CLEARANCE: BELOW COOKTOP
DATUM:
TOP OF COOK SURFACE
TOP VIEW
FRONT VIEW PROFILE VIEW
e
m
l
k
i
d
b
385
g
A
i
j
c
530
f
h
k
POWER OUTLET
CLEARANCE: OVERHEAD CABINET
NOT DIRECTLY ABOVE
CLEARANCE: RANGEHOOD,
OVERHEAD CABINET DIRECTLY ABOVE
n o
P
DATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 179000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 179000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
MAINBOX BLOWERBOX HORIZONTAL ELBOW, 90
Model no:
Auxiliary Modular Ventilation, 13cm, Black - DD13DB1
Auxiliary Modular Ventilation, 13cm, Grey - DD13DG1
Component Description Supplied
Optional Accessory
Mainbox
x1
Blowerbox
x1
Horizontal Elbow, 90°, 00x70*
x1
E90H0X7
Vertical Elbow, 90°, 00x70*
x2
E90V0X7
Duct Adaptor, 90°, 150mm Diameter, 00x70mm*
x1
DA90D0X7D15
Duct Adaptor, 150mm Diameter, 00x70mm*
x1
DA0X7D15
Duct, 1m, 00x70mm*
x1
D100X0X7
Connector, 00x70*
x1
C0X7
Horizontal Elbow, 90°, 00x70mm, Steel**
E90H0X7S
Recirculation Kit
KRCID84
Outlet Adaptor, Blower, 222x89mm
OAB222X89
* Component also available as an optional accessory
** Must be used over a pyrolitic oven
DATA SHEETS | MODULAR COOKTOPS CD1DB1, CD1BG1
VERTICAL ELBOW, 90
DUCT ADAPTOR, 90 DUCT ADAPTOR
CONNECTOR
DUCT
RECIRCULATION KIT
HORIZONTAL ELBOW, 90
STEEL
OUTLET ADAPTOR
The models shown in this Specification Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Specification Guide should not be used as installation guidance for any product. Further information is required to safely and correctly
install the products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com

© FISHER & PAYKEL LIMITED 202 PAGE 189000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 189000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
CD1DB1, CD1BG1
0 100 200 400
millimetres
FRONT VIEW
PROFILE VIEW
b
A
d
g
f
j
k
530
c
h
TOP VIEW
e
k
DATUM:
TOP OF COOK SURFACE
130
124
m
l
I
N
Model no:
Auxiliary Modular Ventilation, 13cm, Black - DD13DB1
Auxiliary Modular Ventilation, 13cm, Grey - DD13DG1
Product Dimensions
mm
a Overall height of mainbox
186
B Overall width of mainbox
10
c Overall depth of mainbox
50
d Height of glass (includes flange and tape)
6
e Corner radius of glass
2
f Height of chassis
180
G Width of lower chassis (includes communication ports)
126
h Depth of chassis
504
i Width from sides of glass to neck of chassis
18
j Depth from front edge of glass to chassis
14
k Depth from back edge of glass to chassis
1
l Height from top of glass to centre of outlet
124
m Depth from front edge of glass to centre of outlet
279
n Width from edge of glass to outside of outlet
6
Product Clearances
mm
Minimum clearance from top surface to top of any appliances, companion
product or obstruction below mainbox
200
Cutout Dimensions*
Proud mm
Flush mm
Overall width of cutout
98
98
Overall depth of cutout
507
509
Overall width of recess
-
14
Overall depth of recess
-
54
Overall height of recess
-
6.5
Recess corner radius
-
4
*Note cutout position is centred to the cooktop.
DATA SHEETS | MODULAR COOKTOPS
MAINBOX

© FISHER & PAYKEL LIMITED 202 PAGE 199000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 199000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
CD1DB1, CD1BG1DATA SHEETS | MODULAR COOKTOPS
Model no:
Auxiliary Modular Ventilation, 13cm, Black - DD13DB1
Auxiliary Modular Ventilation, 13cm, Grey - DD13DG1
Product Dimensions
mm
a Overall height of blowerbox
156
B Overall width of blowerbox (including outlet)
41
C Overall depth of blowerbox
79
D Width of blowerbox
75
E Width from corner to centre of inlet
217
F Depth from corner to centre of inlet
175
g Internal diameter of inlet
154
h Height from base of product to centre of outlet
41
i Width from outside of chassis to centre of outlet
166
j External height of outlet
7
k External width of outlet
0
l Depth of outlet
8
Cutout Dimensions*
mm
Recommended width of cutout **
570
Minimum width of cutout ***
470
Depth of cutout
90
*Blowerbox can be rotated to achieve desired outlet direction, cutout dimensions must be rotated accordingly.
** Recommended width allows greater access to outlet during installation.
*** Clearance only for blowerbox, does not provide allowances for connecting to ducting.
0 100 200 400
millimetres
A
B
C
d
f
e g
h
i
k
j
l
Model no:
Blower Outlet Adaptor - OAB222X89
Product Dimensions
mm
m Height from base of blowerbox to centre of outlet
49
n Width from side of blowerbox chassis to centre of outlet
127
o External height of outlet
91
p External width of outlet
222
m
n
p
o
BLOWER OUTLET ADAPTOR
FOR RECIRCULATION KIT - KRCID834
BLOWERBOX
AS SUPPLIED
BLOWER OUTLET ADAPTOR
Fixed directly to Blowerbox.
SUPPLIED OUTLET
Removed to allow fitting
of Outlet Adaptor
FRONT VIEW PROFILE VIEW
TOP VIEW
PROFILE VIEW

© FISHER & PAYKEL LIMITED 202 PAGE 209000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 209000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
0 100 200 400
millimetres
a
e
g
d
f
h
f
b
352
352
c
DATUM : DUCT INTERFACE
DATUM : DUCT INTERFACE
PROFILE VIEWFRONT VIEW
PLAN VIEW
Optional Part no:
Horizontal Elbow, 90°, 300x70mm - E90H30X7
Product Dimensions
mm
a Overall height of duct
77
B Overall width of duct
52
c Overall length of duct
52
d Internal height of female duct end
74
e Internal width of female duct end
04
f Internal shoulder depth of female duct end
40
G External width of female duct end
07
h Centre Radius of bend
05
E90H0X7DATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 219000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 219000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
0 100 200 400
c
dg
e
f
f
PROFILE VIEWFRONT VIEW
PLAN VIEW
DATUM : DUCT INTERFACE
DATUM : DUCT INTERFACE
DATUM : DUCT INTERFACE
a
137
b
307
137
Optional Part no:
Vertical Elbow, 90°, 300x70mm - E90V30X7
Product Dimensions
mm
a Overall height of ducting
17
B Overall width of ducting
07
c Overall depth of ducting
17
d Internal height of female duct end
74
e Internal width of female duct end
04
f Internal shoulder depth of female duct end
20
G External height of female duct end
74
E90V0X7DATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 229000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 229000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
0 100 200 400
millimetres
h
d
g
e
f
f
PROFILE VIEWFRONT VIEW
PLAN VIEW
DATUM : DUCT INTERFACE
DATUM : DUCT INTERFACE
DATUM : DUCT INTERFACE
a
139
c
240
b
307
Optional Part no:
Duct Adaptor, 90°, 150mm Diameter, 300x70mm - DA90D30X7D15
Product Dimensions
mm
a Overall height of adaptor
19
B Overall width of adaptor
07
c Overall length of adaptor
240
d Internal height of female duct end
74
e Internal width of female duct end
04
f Internal depth of rectangular female duct end
40
G External diameter of round female duct end
150
h Height from bottom of adaptor to centre of outlets
150
DA90D0X7D15DATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 29000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 29000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
0 100 200 400
millimetres
d
h
g
e
f
f
PROFILE VIEWFRONT VIEW
PLAN VIEW
DATUM : DUCT INTERFACE
DATUM : DUCT INTERFACE
DATUM : DUCT INTERFACE DATUM : DUCT INTERFACE
a
150
b
307
c
250
Optional Part no:
Duct Adaptor, 150mm Diameter, 300x70mm - DA30X7D15
Product Dimensions
mm
a Overall height of adaptor
150
B Overall width of adaptor
07
c Overall length of adaptor
250
d Internal height of rectangular female duct end
74
e Internal width of rectangular female duct end
04
f Internal depth of rectangular female duct end
40
G External height of rectangular female duct end
77
h External diameter of round duct female duct end
147
DA0X7D15DATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 249000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 249000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
0 100 200 400
millimetres
c
d
g
e
f
PROFILE VIEW
FRONT VIEW
PLAN VIEW
DATUM : DUCT INTERFACE
DATUM : DUCT INTERFACE
DATUM : DUCT INTERFACE DATUM : DUCT INTERFACE
a
77
b
307
77
Optional Part no:
Connector, 300x70mm - C30X7
Product Dimensions
mm
a Overall height of connector
77
B Overall width of connector
07
c Overall depth of connector
85
d Internal height of connector
74
e Internal width of connector
04
f Internal depth to shoulder
40
G Thickness of internal shoulder divider
5
C0X7DATA SHEETS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 259000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 259000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
0 100 200 400
millimetres
a
d
c
FRONT VIEW
PLAN VIEW
1000
73
b
303
Optional Part no:
Duct, 1m, 300x70mm - D100X30X7
Product Dimensions
mm
a Overall height of ducting
7
B Overall width of ducting
0
c Overall length of ducting
1000
d Corner radius of ducting
9
e Internal height of ducting
70
f Internal width of ducting
00
D100X0X7DATA SHEETS | MODULAR COOKTOPS
f
e

© FISHER & PAYKEL LIMITED 202 PAGE 269000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 269000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
0 100 200 400
millimetres
E90H0X7SDATA SHEETS | MODULAR COOKTOPS
Optional Part no:
Horizontal Elbow, 90°, 00x70mm, Steel - E90H0X7S
Product Dimensions
mm
a Overall height of elbow
120
B Overall width of elbow
50
c Overall depth of elbow
95
d External height of male duct end
74
e External width of male duct end
02
f Depth from front of component to centre of duct
40
G Width from side of elbow to centre of duct
199
h Depth from centre of duct to rear of duct
212
IMPORTANT: Horizontal Steel Elbow must be used over pyrolitic oven.
a
b
c
d
e
f
g
h
HORIZONTAL ELBOW, STEEL
Fitted directly to Mainbox.
SUPPLIED OUTLET
Removed to allow
fitting of elbow
FRONT VIEW PROFILE VIEW
TOP VIEW

© FISHER & PAYKEL LIMITED 202 PAGE 279000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 279000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
KRCID84DATA SHEETS | MODULAR COOKTOPS
Optional Accessory Model no:
Recirculation Kit - KRCID84
Component Description
Quanitity
Filter Box Assembly
x2
Duct Adaptor
x4
Cap
x4
m Flexible Ducting
x1
Product Dimensions
mm
a Overall height of filter box assembly (louvres can be trimmed to
suit kickstrip)
150/10/115/100
B Overall width of filter box assembly
62
c Overall depth of filter box assembly
54
D Height of filter box
98
e Width of filter box at front
46
f Width of filter box at rear
256
G Depth of filter box (excludes bracket)
51
h Depth of bracket flange
1
i Depth of bracket and louvres
26
j Height from bottom of filter box to centre of outlets
49
k Depth from rear of filter box to centre of side outlets
128
l Height from bottom of bracket to lower hole centre
19
m Height between hole centres
60
n Depth from rear of bracket flange to hole centre
7
o Hole diameter
4
p Width of louvres
2
Kickstrip Dimensions
mm
Height of kickstrip (louvres trimmed to suit)
150/10/115/100
Overall width of cutout
47
FRONT VIEW
PLAN VIEW
PROFILE VIEW
G
k
f
D
i
e
C
A
B
h
jl
m
p
n
DATUM : FRONT OF KICKSTRIP
DATUM : FRONT OF KICKSTRIP
CLEARANCE : KICKSTRIP CUTOUT
CLEARANCE : MINIMUM KICK HEIGHT
CLEARANCE :
OPTIONAL KICK HEIGHTS
EXPLODED ISOMETRIC VIEW
DUCT
ADAPTOR
FLEXIBLE
DUCTING
CAP
FILTERBOX
ASSEMBLY
IMPORTANT NOTE
If specifying Recirculation Kit KRCID834 you will
also require the Outlet Adaptor, Blower OAB222X89

© FISHER & PAYKEL LIMITED 202 PAGE 289000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 289000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
INDICATES CABINETRY / PRODUCT DATUM -------------------------
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES CUTOUT -------------------------------------------------------
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read
the installation manual for detailed information on installing the product. For full installation
instructions & specifications visit fisherpaykel.com
qu
sv t
CAP (x2)
FILTER BOX ASSEMBLY (x1)
DUCT ADAPTOR (x2)
Adaptor can be connected to
Flexible Ducting 227 x 94
or
Straight Ducting 222 x 89
PLAN VIEW
EXPLODED ISOMETRIC VIEW
FILTER BOX ASSEMBLY WITH DUCT ADAPTOR AND CAPS - x2 SETS SUPPLIED
Position of caps and adaptors can be interchanged to suit ducting layout
r
DATUM : DUCT INTERFACE
DATUM : DUCT INTERFACE
Optional Accessory Model no:
Recirculation Kit - KRCID84
Product Dimensions
mm
q Distance from edge of duct adaptor to edge of filter box
46
r Internal depth of female end of duct adaptor
4
s Overall length of duct adaptor
227
t Internal length of female end of duct adaptor
22
Overall height of duct adaptor (not shown)
94
Internal height of female end of duct adaptor (not shown)
90
u Thickness of cap from edge of filter box
2
v Length of cap
226
Height of cap (not shown)
9
Kickstrip Dimensions
mm
Height of kickstrip (louvres trimmed to suit)
150/10/115/100
Overall width of cutout
47
KRCID84DATA SHEETS | MODULAR COOKTOPS
PROFILE VIEW
BRACKET LOUVRES
EXPLODED PROFILE VIEW
BRACKET + LOUVRES
DATUM : FLOOR
EXPLODED ISO VIEW
FILTER BOX, BRACKETS
+ LOUVRES
FILTER BOX
DATUM : OPTIONAL
KICK HEIGHTS
h
100
j
115
l
10
n
150

© FISHER & PAYKEL LIMITED 202 PAGE 299000269B PLANNING GUIDE MODULAR COOKTOPS - VERSION B - OCTOBER 202
PRODUCT DECISIONS

© FISHER & PAYKEL LIMITED 202 PAGE 09000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
PAIRING GUIDE
Available
not suitable downdraft not sufficient
#
Cannot combine downdraft with rangehood units
* Not possible connect 2 overhead ventilation units with a primary cooktop
+ 2 different rangehood widths need to be combined
** One rangehood could be connected, the second would have to be manually operated.
VENTILATION CHOICE - DOWNDRAFT OR INSERT RANGEHOOD OR WALL RANGEHOOD
#
CONNECTED * NOT CONNECTED
AUXILIARY
COOKTOP
0-2
COMBINED
COOKTOP
WIDTH
AUXILIARY
DOWNDRAFT
VENTILATION
1-2
INSERT RANGEHOOD
x1
WALL RANGEHOOD
x1
INSERT RANGEHOOD**
glass
INSERT RANGEHOOD
shallow
stainless
INSERT RANGEHOOD
deep
stainless
MODELS
CI02D
CIT02DX1
CI92D
CI92DX1
DOWNDRAFT
CD1D
Recirculation
option
60cm
HP60IDCHX4
HP60IDCHEX4
90cm
HP90IDCHX4
HP90IDCHEX4
60cm
HC60DCXB4
90cm
HC90DCXB4
HC90DCBB4
HC90DCEBB4
HC90DCEXB4
120cm
HC120DCXB4
60cm
HP60IDCHX4
HP60IDCHEX4
90cm
HP90IDCHX4
HP90IDCHEX4
60cm
HPB6028-1
90cm
HPB9028-1
90cm
HPB9048-2
120cm
HPB12048-2
PRIMARY COOKTOP x1
9 CM x0 9cm 1 1 1 1
CI92DTT x1 0cm 69cm 1 1 1 1
x1 9cm 78cm 1 1 1 1
x2 0cm 99cm 2 1 2 2 1
x2 9cm 127cm 2 1 1 1 1
60 CM x0 60cm 2 1 1 1
CI604DTT x1 0cm 90cm 2 1 1 1 1
x1 9cm 99cm 2 1 2 2 1
x2 0cm 120cm 2 1 2 2 1
x2 9cm 18cm 2 1 1 1 1
76 cm x0 76cm - 1 1 1
CI764DTT x1 0cm 106cm - 1 2 2 1
x1 9cm 115cm - 1 2 2 1
x2 0cm 16cm - 1 1 1 1 2
x2 9cm 154cm - 2 2 2
90 cm x0 90cm - 1 1 1 1
CI905DTT x1 0cm 120cm - 1 2 2 1
x1 9cm 129cm - 1 1 1 1 2
x2 0cm 150cm - 1 1 1 1 2
x2 9cm 168cm - 2 2 2
+
+
+
+
+
+
+
+
+
+
PRODUCT DECISIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 19000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
MODULAR SYSTEM CAPABILITIES
PRIMARY COOKTOP
Touchscreen user interface.
Controls complete modular suite.
Available in 39cm, 60cm, 76cm and 90cm widths.
AUXILIARY COOKTOP
No user interface.
Must be paired with a primary cooktop.
Controlled by the primary cooktop.
Available in 30cm and 39cm widths.
AUXILIARY VENTILATION
Downdraft has no user interface and must be paired
with and controlled by the primary cooktop.
Overhead can be controlled by the primary cooktop.
+
_
+
_
CONNECTED EXPERIENCE
INDUCTION INDUCTION
TEPPANYAKI DOWNDRAFT
OVERHEAD
MIX AND MATCH EITHER OR
ESSENTIAL
1x MAXIMUM
RECOMMENDED
OVERHEAD 1x
DOWNDRAFT 1-2x
OPTIONAL
0-2x
PRODUCT DECISIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 29000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
DOWNDRAFT VENTILATION
The modular ventilation unit is a downdraft ventilation system that
efficiently extracts air across and downwards.
The modular ventilation unit provides efficient ventilation to adjacent
cook zones. Consideration of cook zone layout and cook module size
is critical for optimum pairing of ventilation type and quantity.
IMPORTANT: Where modular ventilation is unable to provide efficient
venting it is recommended that overhead extraction is chosen.
WARNING: The Modular Ventilation unit cannot be used alongside a
gas cooktop.
MODULAR VENTILATION CAPABILITIES
SUFFICIENT VENTILATION
ADJACENT COOKZONES ARE EFFECTIVELY VENTED
INSUFFICIENT VENTILATION
NON-ADJACENT COOKZONES ARE NOT SUFFICIENTLY VENTED
0cm + 9cm MODULES
60cm PRIMARY MODULE WITH 2x DOWNDRAFT
60cm PRIMARY MODULE WITH 1x DOWNDRAFT
76cm PRIMARY MODULE WITH 2x DOWNDRAFT
90cm PRIMARY MODULE WITH 2x DOWNDRAFT
TOP VIEW
FRONT VIEW
PRODUCT DECISIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 9000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
VENTILATION CHOICE
VENTILATION TYPE PRIMARY COOKTOP
PAIRED FOR OPTIMUM VENTILATION
CHOICE DETERMINED BY VENTILATION CAPABILITIES
VISUAL POSITION
VENTILATION POSITION
90cm PRIMARY
76cm PRIMARY
60cm PRIMARY
2x Downdraft
9cm PRIMARY
1x Downdraft minimum
DOWNDRAFT
OVERHEAD
VISUAL ELEMENT ABOVE COOK SURFACES
NO VISUAL ELEMENT ABOVE COOK SURFACES
PRODUCT DECISIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 49000269B PLANNING GUIDE MODULAR COOKTOPS - VERSION B - OCTOBER 202
PLANNING CONSIDERATIONS

© FISHER & PAYKEL LIMITED 202 PAGE 59000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 59000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
INSTALLATION DIMENSIONS
PRODUCT DIMENSIONS
mm
A Nominal bench depth* min 700
B Nominal distance from front of bench to front of cooktop 60
C Distance between modules 2
D Distance between edge of module and edge of recess 2
E Corner radii of cutout max 10
F Corner radii of recess 4
* Based on nominal distance 'B', where cabinetry constructed from 19mm panels and ducting routes to rear of cabinet.
Can be reduced to 600, see 'Cabinetry Considerations' page for details.
INSTALLATION OVERVIEW
INSTALLATION OVERVIEW
a
b
c
d
E
f
JOINER BAR
Required between modules,
supplied with auxiliary modules.
PRIMARY COOKTOP
AUXILIARY VENTILATION
AUXILIARY COOKTOP
PLANNING CONSIDERATIONS | MODULAR COOKTOPS
d
IMPORTANT NOTE
Cutout widths and radii may not be possible in certain benchtop materials. Please refer to
benchtop suppliers material specifications and fabrication parameters.

© FISHER & PAYKEL LIMITED 202 PAGE 69000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
COMBINED INSTALLATION PLANNING
A
e
d
c
b
F
b
A
OVERALL WIDTH OF MODULES = COMBINED PRODUCT WIDTHS
add module widths
+ GAPS BETWEEN MODULES
2mm x (number of modules -1)
b
WIDTH OF CUTOUT
FLUSH AND PROUD
= OVERALL WIDTH OF MODULES - LEFT OVERHANG
19mm Induction / Teppanyaki OR
16mm Downdraft
- RIGHT OVERHANG
19mm Induction / Teppanyaki OR
16mm Downdraft
c
DEPTH OF CUTOUT
PROUD
= 507mm
b
WIDTH OF CUTOUT
FLUSH AND PROUD
= OVERALL WIDTH OF MODULES - LEFT OVERHANG
19mm Induction / Teppanyaki OR
16mm Downdraft
- RIGHT OVERHANG
19mm Induction / Teppanyaki OR
16mm Downdraft
d
DEPTH OF CUTOUT
FLUSH
= 509mm
e
WIDTH OF RECESS
FLUSH
= OVERALL WIDTH OF MODULES + 4mm
2mm each side
f
DEPTH OF RECESS
FLUSH
= 54mm = 50mm
product depth
+ 4mm
2mm top and bottom
COMBINED BENCHTOP EQUATIONS
Pairings of modular products have been designed to fit in a singular benchtop cutout. When grouping modules it is essential to calculate their
combined cutout requirements. The following equations can be used to guide calculations.
For dimensions of common configurations please refer to subsequent pages.
FLUSH PROUD MODULES
PLANNING CONSIDERATIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 79000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 79000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
TYPICAL CONFIGURATIONS WITH MODULAR VENTILATION
5 THREE IN A ROW WITH MODULAR VENTILATION - 60+30+30
Dimensions
W x D x H
Combined Module Size
1468 x 50 x 180
Recess, flush 1472 x 54 x 6.5
Cutout, flush 140 x 509
Cutout, proud 140 x 507
1 SINGLE WITH MODULAR VENTILATION - 39
Dimensions
W x D x H
Combined Module Size
517 x 50 x 180
Recess, flush
521 x 54 x 6.5
Cutout, flush*
482 x 509
Cutout, proud*
482 x 507
*Cutout width not central to overall width of modules. Offset
specific to placement of downdraft unit to the left or right. Side
overhangs differ for downdraft and cooktop - downdraft 16mm,
cooktops 19mm. Refer 'Benchtop Installation Details' for more
information.
9cm
4 THREE IN A ROW WITH MODULAR VENTILATION - 39+39+39
Dimensions
W x D x H
Combined Module Size
142 x 50 x 180
Recess, flush
1427 x 54 x 6.5
Cutout, flush
185 x 509
Cutout, proud
185 x 507
3 THREE IN A ROW WITH MODULAR VENTILATION - 39+30+30
Dimensions
W x D x H
Combined Module Size
125 x 50 x 180
Recess, flush
1257 x 54 x 6.5
Cutout, flush
1215 x 509
Cutout, proud
1215 x 507
3
4
5
600
2 TWO IN A ROW WITH MODULAR VENTILATION - 39+39
Dimensions
W x D x H
Combined Module Size
904 x 50 x 180
Recess, flush
908 x 54 x 6.5
Cutout, flush*
862* x 509
Cutout, proud*
862* x 507
*Glass overhang at sides adjusted to fit 900mm cabinet. Dimensions
specific to 900 cabinet constructed from 19mm panels. 866W
cutout recommended if cabinetry construction allows.
6 THREE IN A ROW WITH MODULAR VENTILATION - 60+39+39
Dimensions
W x D x H
Combined Module Size
168 x 50 x 180
Recess, flush 1642 x 54 x 6.5
Cutout, flush 1600 x 509
Cutout, proud 1600 x 507
1 2
6
600 600600 600 600
900
600
9cm9cm 0cm 9cm 0cm
9cm 9cm 9cm
0cm 60cm 0cm
9cm 60cm 9cm
SINGLE - COMPACT <600
TWO IN A ROW - MID 900
THREE IN A ROW - WIDE >1200
THREE IN A ROW - EXTRA WIDE >1450
IMPORTANT NOTE
Other configurations are possible. Cutout widths may not be possible in certain benchtop materials. Please
refer to benchtop suppliers material specifications and fabrication parameters.
PRIMARY COOKTOP
AUXILIARY COOKTOP
AUXILIARY VENTILATION
PLANNING CONSIDERATIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 89000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
TYPICAL CONFIGURATIONS WITH OVERHEAD VENTILATION
1 TWO IN A ROW - 39 + 39
Dimensions
W x D x H
Combined Module Size
772 x 50 x 74
Recess, flush
776 x 54 x 6.5
Cutout, flush
74 x 509
Cutout, proud
74 x 507
2 TWO IN A ROW - 60 + 30
Dimensions
W x D x H
Combined Module Size
902 x 50 x 58
Recess, flush
906 x 54 x 6.5
Cutout, flush *
862* x 509
Cutout, proud *
862* x 507
*Glass overhang at sides adjusted to fit 900mm
cabinet. Dimensions specific to 900 cabinet
constructed from 19mm panels. 866W cutout
recommended if cabinetry construction allows.
5 TWO IN A ROW - 76 + 39
Dimensions
W x D x H
Combined Module Size
1147 x 50 x 74
Recess, flush
1151 x 54 x 6.5
Cutout, flush
1109 x 509
Cutout, proud
1109 x 507
3 TWO IN A ROW - 60 + 39
Dimensions
W x D x H
Combined Module Size
987 x 50 x 74
Recess, flush 991 x 54 x 6.5
Cutout, flush 949 x 509
Cutout, proud 949 x 507
4 TWO IN A ROW - 76 + 30
Dimensions
W x D x H
Combined Module Size
1062 x 50 x 74
Recess, flush 1066 x 54 x 6.5
Cutout, flush 1024 x 509
Cutout, proud 1024 x 507
6 TWO IN A ROW - 90 + 30
Dimensions
W x D x H
Combined Module Size
1202 x 50 x 74
Recess, flush
1206 x 54 x 6.5
Cutout, flush
1164 x 509
Cutout, proud
1164 x 507
7 THREE IN A ROW - 60 + 30 + 30
Dimensions
W x D x H
Combined Module Size
1204 x 50 x 74
Recess, flush
1208 x 54 x 6.5
Cutout, flush
1166 x 509
Cutout, proud
1166 x 507
9 THREE IN A ROW - 76 + 30 + 30
Dimensions
W x D x H
Combined Module Size
164 x 50 x 74
Recess, flush
168 x 54 x 6.5
Cutout, flush
126 x 509
Cutout, proud
126 x 507
8 TWO IN A ROW - 90 + 39
Dimensions
W x D x H
Combined Module Size
1287 x 50 x 74
Recess, flush
1291 x 54 x 6.5
Cutout, flush
1249 x 509
Cutout, proud
1249 x 507
"1 THREE IN A ROW - 90 + 30 + 30
Dimensions
W x D x H
Combined Module Size
1504 x 50 x 74
Recess, flush
1508 x 54 x 6.5
Cutout, flush
1466 x 509
Cutout, proud
1466 x 507
"0 THREE IN A ROW - 60 + 39 + 39
Dimensions
W x D x H
Combined Module Size
174 x 50 x 74
Recess, flush
178 x 54 x 6.5
Cutout, flush
16 x 509
Cutout, proud
16 x 507
600 600
900 600 600
760 760
760 760
6
7
8
1 3
94
5
2
"0
"1
60cm 9cm9cm 9cm
60cm 0cm 76cm 0cm
76cm 9cm
60cm 0cm 0cm
90cm 0cm
76cm 0cm
90cm
0cm
9cm 60cm 9cm 9cm
0cm 0cm
90cm
MID <900 WIDE <1200
EXTRA WIDE >1200
PRIMARY COOKTOP
AUXILIARY COOKTOP
PLANNING CONSIDERATIONS | MODULAR COOKTOPS
IMPORTANT NOTE
Other configurations are possible. Cutout widths may not be possible in certain benchtop materials. Please refer to benchtop suppliers
material specifications and fabrication parameters.

© FISHER & PAYKEL LIMITED 202 PAGE 99000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
16mm
19mm
BENCHTOP INSTALLATION DETAILS
2mm
6.5mm
16mm
18mm
10.5mm
12.5mm
2mm
6.5mm
11.5mm
FRONT VIEW PROFILE VIEW FRONT VIEW
SIDE OVERHANGS
INDUCTION + TEPPANYAKI MODULES DOWNDRAFT MODULE
FRONT + REAR OVERHANG
ALL MODULES
BENCH DETAIL
PROUD FLUSH
BENCHTOP INSTALLATION
A flush or proud finish between the top surface of the modules
and benchtop is achievable.
Some overhang details are common left to right or front to back,
however there are small dimensional changes between proud and
flush, cooking modules and ventilation module.
Care needs to be taken during planning and fabrication to ensure
successful installation of modules
Shimming may be required during flush installation.
PLANNING CONSIDERATIONS | MODULAR COOKTOPS
2mm
6.5mm
19mm
21mm
FOAM TAPE
SHIM

© FISHER & PAYKEL LIMITED 202 PAGE 409000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 409000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
CLAMPS
Clamps are suplied with modules to secure
their postition to benchtop. There are two
types, common and rear downdraft.
It is recommended to have 10mm clearance
from edge of cutout for clamp engagement.
Clamps are attached to chassis at fixed hole
locations. A minimum of 2 clamps are required
per module, it is recommended they are
positioned on opposite sides of each module
eg. left and right or front and rear.
For more details please refer to Install Guide.
CLAMP FIXING LOCATIONS
PLAN VIEW
Minimum of 2 clamps per module.
DETAIL A
Can be rotated and
moved horizontally
ISO FRONT VIEW
ISO REAR VIEW
SIDE VIEW
CLEARANCE REQUIREMENTS
ALL MODULES
BRACKET TYPES
COMMON BRACKET REAR DOWNDRAFT BRACKET
Applies to all bracket locations, exluding rear downdraft
10mm
25mm
10mm
9cm 60cm0cm 76cm 90cm9cm 9cm0cm
DETAIL B
Bracket can be be
repositioned vertically
A
B
C
DETAIL C
Minimum clearance common to all
brackets left/right and front/rear
PLANNING CONSIDERATIONS | MODULAR COOKTOPS CLAMPING LOCATIONS

© FISHER & PAYKEL LIMITED 202 PAGE 419000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
COOKTOP VENTILATION REQUIREMENTS
VENTILATION OVERVIEW
The cook modules require ventilation to allow cooling of the
electronic components within the chassis. Cooling fans are located
on the base of the product drawing cool air into the rear of the
product while hot air exits from vents at the front.
Provisions need to be made in cabinetry to allow fresh air to enter
and hot air to exit to ensure product ventilation and optimum
product performance.
When multiple products are installed their individual ventilation
requirements must also be combined.
CLEARANCE REQUIREMENTS mm
a Clearance below chassis from top of cook surface
- Induction 72
- Teppanyaki 86
VENTILATION REQUIREMENTS
INTAKE at rear mm cm
2
B via service channel, min depth
20 -
c through adjacent cabinets, per side wall*
2x Ø50 40
OUTLET at front* w x h cm
2
D 4mm gap along width of chassis
30cm cook module 255 x 4 10
39cm cook module 40 x 4 14
60cm cook module 555 x 4 22
76cm cook module 715 x 4 0
90cm cook module 855 x 4 4
* vents with equivlent-sized area possible. Must be positioned in front of
product.
VENTILATION OUTLET
Hot air from cook modules must be able to exit at front of cabinets, the
most direct route is recommended.
The detail below shows one solution where cutouts have been made in
the support rail at front of cabinet, other routes are possible but must
meet dimensional guidelines in table.
VENTILATION REQUIREMENTS
Air intake at rear, outlet at front
CLEARANCE REQUIREMENTS
Modules require clearance
below chassis to ensure air flow.
A
FRONT REAR
INTAKE OPTION A:
SERVICE CHANNEL
Fresh air is drawn up from
the kick cavity through
service channel at rear of
cabinetry.
If cavities are tightly sealed,
ventilation holes in kick panel
are required.
INTAKE OPTION B:
ADJACENT CABINETS
2x Ø50 holes are required
in each side wall through to
adjacent cabinets. Total of 4x
holes required.
b
c
SIDE VIEW
50mm
BENCHTOP
RAIL
FRONT PANEL
AIR VENT
D
DETAIL 1
SIDE VIEW
1
1
PLANNING CONSIDERATIONS | MODULAR COOKTOPS
FRONT VIEW
DATUM:
WIDTH OF CHASSIS
RAIL
Single cutout in rail, full width of
chassis, 4mm high.
Example of alternate cutout
where equivalent ventilation
area is achieved.
EXAMPLE VENTILATION CUTOUTS

© FISHER & PAYKEL LIMITED 202 PAGE 429000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
MINIMUM BENCH DEPTH ON FLOOR BLOWER SUB FLOOR BLOWER
ON FLOOR BLOWER,
STRAIGHT ADAPTER
90 DEGREE ADAPTER STRAIGHT ADAPTER
CABINETRY DIMENSIONS
mm
A Bench depth with ducting
routed within cabinet*
min 600
B Bench depth with ducting
routed through service channel*
min 700
C Nominal distance from front of
bench to front of cooktop
60
D Kick height when ducting
routed through kick cavity**
min 80
E Kick height when blower
positioned in sub floor.
min 0
F Internal depth of cabinet 560
G Depth of service cavity min 80
* Cabinetry constructed from 19mm panels.
** 100mm minimum kick height when using
Recirculation Kit - KRCID834
MODULAR VENTILATION CABINETRY OVERVIEW
CRITICAL NOTE
It is essential to work with CAD downloads
of modular ventilation components to
design a ducting layout best suited to
specific cabinetry requirements.
b
b
C
C
f G
D
E
FRONT PANEL
CARCASS REAR
PANEL
SERVICE CHANNEL
BENCHTOP WITH
CUTOUT
FLOOR
SUB FLOOR
EG. BASEMENT
d
a
c
CABINETRY OVERVIEW
These are representational illustrations
of cabinetry and minimal ducting to
provide minimum cabinetry guidelines.
Benchtop depths are driven by ducting
requirements within cabinetry.
Other ducting layouts are possible.
Benchtop and cabinetry dimensions
should be adapted to suit requirements
specific to location, materials and
construction methods. Cabinetry may
need to be adapted with features such
as cutouts, false panels, shelf and
drawer modifications.
ISO VIEW
SIDE VIEW
SIDE VIEW
SIDE VIEW
SIDE VIEW
ISO VIEW
ISO VIEW
PLANNING CONSIDERATIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 49000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
MODULAR VENTILATION COMPONENTS
The mainbox can vent to the left or right.
The blowerbox can be rotated 60
MODULAR VENTILATION
KEY COMPONENTS
MODULAR VENTILATION SYSTEM
OVERVIEW WITH DUCTING COMPONENTS
VERTICAL ELBOW, 90
STRAIGHT DUCTING
Cut to length
DUCT ADAPTER
JOINER
ALTERNATE
ATTACHMENTS TO
DOWNDRAFT MAINBOX
ADDITIONAL
STRAIGHT DUCTING
HORIZONTAL
ELBOW, 90
DUCT ADAPTER, 90
OUTLET
VERTICAL ELBOW, 90
DOWNDRAFT MAINBOX
BLOWERBOX
INTAKE
IMPORTANT
Blowerbox inlet and outlet are offset, component is not symmetrical.
CARE TO BE TAKEN WHEN PLANNING
ADAPTER
CHOICE
HORIZONTAL ELBOW, 90, STEEL
Optional accessory. Must be used over
pyrolytic oven.
PLANNING CONSIDERATIONS | MODULAR COOKTOPS
JOINER
NOTE
Indicative layout, other
configurations are
possible.
CRITICAL NOTE
It is essential to work with CAD downloads of modular ventilation components
to design a ducting layout best suited to specific cabinetry requirements.

© FISHER & PAYKEL LIMITED 202 PAGE 449000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
MAINBOX WITH DUCTING
TYPICAL DUCTING WITH MODULAR VENTILATION DIMENSIONS
WIDTH DIMENSIONS DEPTH DIMENSIONS
DUCT LEFT DUCT RIGHT DUCT REAR
BLOWERBOX VENT DIRECTION
VENT REAR VENT RIGHT VENT LEFT
FRONT VIEW SIDE VIEW
Ducting dimensions
common left and
right
408
254
0min
27
617
0min
189
4
47
158
217
175
204
158
75
8
205 217
175
79
41
21
166
SIDE VIEW
FRONT VIEW
FRONT VIEW
478
41
56
471
12
502
56
471
478
41
15
52
524
459
494
429
111
485
FRONT VIEW
SIDE VIEW
REAR VIEW
SIDE VIEW
TOP VIEW
IMPORTANT NOTE
Extra attention is required during planning of blower placement in
relation to cabinetry due to asymmetry of intake and outlet.
BLOWER BOX
INTAKE AND OUTLET POSITIONS
CONSIDERATIONS
The ducting configuration
shown is a basic layout.
Dimensions stated are to
provide a starting point
for product placement and
space requirements.
Other configurations
are possible. Additional
ducting can be added to
the system.
DATUM: FLOOR
DATUM: 80MM
minimum kick height
PLANNING CONSIDERATIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 459000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 459000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
TYPICAL CONFIGURATIONS WITH MODULAR VENTILATION AND DUCTING
LAYOUTS APPLY TO BOTH A 9CM AND 60CM CENTRAL COOKTOP MODULE
9cm
600 600 600600 600 600
900
600
9cm9cm 0cm 9cm 0cm
9cm 9cm 9cm
0cm 60cm 0cm
9cm 60cm 9cm
SINGLE - COMPACT < 600 TWO IN A ROW - MID < 900 THREE IN A ROW - WIDE > 1200
SPACE REQUIREMENTS
These are representational
illustrations of typical
configurations with modular
ventilation and ducting installed
in standardised cabinetry widths
to provide an overview of
cabinetry requirements. Other
configurations are possible.
IMPORTANT
A full assessment should be
undertaken of chosen modular
components within cabinetry
dimensions specific to location,
materials and construction
methods.
BLOWERBOX PLACEMENT
SUB-FLOOR BLOWER BOX ON FLOOR BLOWER BOX
Ducting can also exit to left.
Ducting can also exit to left.
Ducting can also exit to left.
Configurations can not be mirrored. Layout determined due to
asssymetry of blower box.
Layout can be mirrored.
PRIMARY COOKTOP
AUXILIARY COOKTOP
AUXILIARY VENTILATION
PLANNING CONSIDERATIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 469000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
BLOWERBOX CABINETRY
470 MINIMUM
570 RECOMMENDED
90 MINIMUM
ISOMETRIC VIEW
PLAN VIEW
CABINETRY FLOOR PANEL BLOWERBOX
BLOWERBOX CUTOUT
The Blowerbox requires a minimum cutout of 390mm x 470mm in base
of cabinetry so it can be positioned on the floor.
For ease of installation and connection to outlet ducting it is
recommended that the cutout is increased to 390mm x 570mm.
IMPORTANT
The position of the cutout may not be central to floor panel.
Pre-planning is required.
BLOWER BOX INSTALLATION OVERVIEW
1
Cut hole in bottom
of cabinetry panel
2
Lower blowerbox
onto floor.
3
Oversized hole
allows access to
connect ducting
4
Repostition blowerbox
to achieve alignment
with ducting.
PLANNING CONSIDERATIONS | MODULAR COOKTOPS
CONNECTOR

© FISHER & PAYKEL LIMITED 202 PAGE 479000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202 © FISHER & PAYKEL LIMITED 202 PAGE 479000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
SERVICES
PRIMARY MODULAR INDUCTION COOKTOP, 39CM,
2 ZONES WITH SMARTZONE
Model no:
CI92DTTB1 Black
CI92DTTG1 Grey
Dimensions
mm
Power Cable
1700
PRIMARY MODULAR INDUCTION COOKTOP, 60CM,
4 ZONES WITH SMARTZONE
Model no:
CI92DTTB1 Black
CI92DTTG1 Grey
Dimensions mm
Power Cable not supplied
PRIMARY MODULAR INDUCTION COOKTOP, 76CM,
4 ZONES WITH SMARTZONE
Model no:
CI92DTTB1 Black
CI92DTTG1 Grey
Dimensions
mm
Power Cable
not supplied
PRIMARY MODULAR INDUCTION COOKTOP, 90CM,
5 ZONES WITH SMARTZONE
Model no:
CI92DTTB1 Black
CI92DTTG1 Grey
Dimensions
mm
Power Cable
not supplied
FRONT VIEW
TOP VIEW
FRONT VIEW
TOP VIEW
FRONT VIEW
TOP VIEW
FRONT VIEW
TOP VIEW
POWER CABLE
COMMUNICATION PORT
PLANNING CONSIDERATIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 489000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
SERVICES
AUXILIARY MODULAR TEPPANYAKI COOKTOP,
30CM, 2 ZONES
Model no:
CIT02DX1
Dimensions
mm
External Communication Harness*
500
Power Cable*
1700
* x1 supplied with each auxiliary unit
AUXILIARY MODULAR INDUCTION COOKTOP,
30CM, 2 ZONES WITH SMARTZONE
Model no:
CI02DB1 Black
CI02DG1 Grey
Dimensions
mm
External Communication Harness*
500
Power Cable*
1700
* x1 supplied with each auxiliary unit
AUXILIARY MODULAR TEPPANYAKI COOKTOP,
39CM, 2 ZONES
Model no:
CI92DX1
Dimensions
mm
External Communication Harness*
500
Power Cable*
1700
* x1 supplied with each auxiliary unit
AUXILIARY MODULAR INDUCTION COOKTOP,
39CM, 2 ZONES WITH SMARTZONE
Model no:
CI92DB1 Black
CI92DG1 Grey
Dimensions
mm
External Communication Harness*
500
Power Cable*
1700
* x1 supplied with each auxiliary unit
AUXILIARY MODULAR VENTILATION, 13CM
Model no:
CD1DB1 Black
CD1DG1 Grey
Dimensions
mm
External Communication Harness*
500
Central Communication Harness*
1700
Power Cable
000
* x1 supplied with each auxiliary unit
FRONT VIEW
TOP VIEW
FRONT VIEW
TOP VIEW
FRONT VIEW
TOP VIEW
FRONT VIEW
TOP VIEW
FRONT VIEW
TOP VIEW
EXTERNAL COMMUNICATION HARNESS
CENTRAL COMMUNICATION HARNESS
POWER CABLE
PLANNING CONSIDERATIONS | MODULAR COOKTOPS

© FISHER & PAYKEL LIMITED 202 PAGE 499000269B PLANNING GUIDE MODULAR COOKTOPS VERSION B - OCTOBER 202
The models shown in this Planning Guide may not be available in all markets and are subject to change at any time. Product specifications may vary from those shown. This Planning Guide should not be used as installation guidance for any product. Further information is required to safely and correctly install the
products featured here. Specific installation guidance will be available with the product on delivery and on our website fisherpaykel.com
MODULAR CONNECTIONS
FRONT VIEW
TOP VIEW
EXTERNAL COMMUNICATION HARNESS
CENTRAL COMMUNICATION HARNESS
POWER CABLE
SUPPLIED HARNESS
External communication harnesses connect
auxiliary modules to the primary module. These
connections must be to the product directly
adjacent in a 'daisy chain' configuration (refer
diagram).
1x External communication harness is supplied
with each auxiliary module (induction,
teppanyaki and downdraft ventilation).
1x Central communication harness is supplied
with auxiliary modular ventilation to connect
downdraft mainbox with blowerbox.
PLANNING CONSIDERATIONS | MODULAR COOKTOPS