Tools and Parts
Parts supplied
Removing the packaging
CAUTION!
Remove carton carefully, wear gloves to protect against sharp
edges.
WARNING!
Remove the protective lm covering the product before putting
into operation.
• Hood canopy assembly with blower and LED lamps already
installed.
• 6” (15.2 cm) round air transition
• Duct covers
• Hardware bag with:
Part Qty Part Qty
5x45 mm
6
4.2x8 mm
4
8x40 mm
6
Duct cover bracket
1
3.5x9.5 mm
2
Mounting template
1
10x60 mm
4
5.4 x 75 mm
4
Tools/Materials required
• Level
• Drill with 1¼” (3.2 cm),
1
⁄8” (3.2 mm), and
1
⁄16” (4,8 mm) drill bits
• Pencil
• Wire stripper or utility knife
• Tape measure or ruler
• Pliers
• Caulking gun and weatherproof caulking compound
• Vent clamps
• Jigsaw or keyhole saw
• Flat-blade screwdriver
• Metal snips
- Phillips
- Torx 20 screwdriver
Parts needed
• Home power supply cable
• ½” (12.7 mm) UL listed or CSA approved strain relief
• 2 UL listed wire connectors
For vented installations, you will also need:
• 1 wall or roof cap
• Metal vent system
Parts not supplied
Optional Accessories
Kit # Part Kit # Part
No Return
Valve Kit
KIT0102873
CFM
Reduction Kit
KIT02748
Recirculating
Kit
KIT0102875
Long Chimney
Extention Kit
KIT01935
Product Dimensions
E
C
D
H
B
A
G
F
ALS430SSB ALS436SSB
A
30”
(76 cm)
36”
(91.2 cm)
B 19
11
⁄16” (50 cm)
C*
max. 42
9
⁄16” (108.1 cm)
min. 28
17
⁄64” (71.8 cm)
D**
max. 38
45
⁄64” (98.3 cm)
min. 24
39
⁄64” (62.5 cm)
E 6” (15.24 cm)
F 10
19
⁄32” (26.9 cm)
G 13
5
⁄64” (33.2 cm)
H 1
37
⁄64” (4 cm)
*For non-vented (recirculating installations)
**For vented installations