9. Fix Front cover to control housing using the 4xM4 screws
provided.
10. Main Power supply connection is to completed in line
with instructions in the “Power supply installation”
section of this manual.
1. Connect gas inlet fitting to mains gas supply in
accordance with local gas installation code and gas
supply installation section of manual. Leak test with
soapy water.
For White Rodger
Insert Black Ignitor Cable directly into Control Box at
terminal marked:
Insert White Ionisation Cable directly into Control
Box at terminal marked:
Insert Earth Terminal over Earth Tab, attached to
side of Wall Bracket Housing and marked with the
symbol:
INSTALLATION INSTRUCTIONS CONTINUED...
IMPORTANT
After gas installation and electrical installation is complete,
all gas lines should be tested for leaks using a soapy water
solution. See Section titled “Leakage Test” for further
information. Ensure gas pressure meets the requirements
outlined in Gas Supply Installation above.
!
IMPORTANT
Ensure that a water tight seal is maintained.
!
White Rodger