Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/81744888-im-65ne-25/bgb.png)
9
ENGLISH
4) Either mix 5 litres of water with 18 ml of 5.25% sodium hypochlorite solution in a suitable container, or the recommended
Hoshizaki sanitiser as directed.
5) Soak a clean sponge or cloth with the solution, and wipe the bin liner, bin door and slope.
6) The remaining solution can be used to sanitise utensils.
Note: Do not wipe dry or rinse after sanitising, but allow to air dry.
[d] Air Filter
Plasticmeshairltersremovedirtordustfromtheair,andkeepthecondenserfromgettingclogged.Iftheltersgetclogged,
theicemaker’sperformancewillbereduced.Removeandcleantheairlter(s)atleasttwicepermonth:
1)Slidetheairlteroffthelterguide[IM-21CNE/30CNE]orthelouver[IM-45CNE/45NE/65NE/100CNE/100NE/130NE/240NE].
2)Cleantheairlterbyusingavacuumcleaner.Whenseverelyclogged,usewarmwaterandaneutralcleanertowashtheair
lter.
3)Rinseanddrytheairlterthoroughly.
NOTICE
Aftercleaning,besuretoplacetheairlterbackinposition.
Air Filter
Louver
* Figure shows IM-240NE
[IM-45CNE/45NE/65NE/100NE/130NE/240NE]
Air Filter
Filter Guide
Slide in/out
[IM-21CNE/30CNE]
[IM-100CNE]
Air Filter
Louver
2. BEFORE CALLING FOR SERVICE
WARNING
Do not damage the refrigerant circuit.
[a] Error Code Indication
If the error code “E” is indicated on the display, before calling for service, check the following.
Code Remedy
E1 Freezeerror.Unplug unit and plugit back in after3 minutes. Clean airlter.Lowerambient temperature orensure
adequate clearance around unit (see "I. 4. LOCATION"). If error persists, call for service.
E2 Defrost error. Unplug unit and plug it back in after 3 minutes. If error persists, call for service.
EE Othererror. Unplugunitand plug it back in after3 minutes. Clean air lter. Check for water failure orclosed water
supply tap. Lower ambient temperature or ensure adequate clearance around unit (see "I. 4. LOCATION"). If error
persists, call for service.
Loading ...