Performance Data Sheet
SmartWaterFiltrationSystem
GSWF Cartridge
Thissystemhas been testedaccordingto NSF/ANS142/53for reduction of the substanceslisted below.
Theconcentrationof the indicated substancesin water entering thesystem was reduced to a concentration
less thanorequal to thepermissible limit for water leaving the system,as specified inNSF/ANS142/53.*
(100%safety factors built in for unmetered usage)
Parameter
(:hlorin(
T & ()
Particulale*':
Parameter
Turbidity
Cysts
I.ead aI pH 6.5
Lead aI pH 8.5
Lindane
A1F,izine
USEPA
MCL
USEPA
hlfluent
Average
1.845 mgiI.
143,333 #imI
Influent
Standard No. 42: Aesthetic Effects
hafluent Challenge
Concentration
2.9 mgiL+19%
at least 10,000pardcles/mL
Standard No. 53: Health Effects
Iilfhlent Clr,dlenge Effluent
Effluent
Average MaxiIllttnl
< 0.05 mgiI. 0.05 mgiL
29.83 #imL 140 #imI.
% Reduction
Average Mitmnum
> _ 7.2_ % 96.43!'{
99.98!'_ 99.91%
_, Reduction
Mha. Required
Reduction
> 50%
>85%
Min. Required
MCL
1 N'FU***
99.95% Reduction
0.015 mgiL
0.015 mgiL
0.0902 mgiL
9.007 mgiL
Average
19.3 N'F[ ;'::**
200,000 #iL
0.15 mgiL
0.14 mgiI
0.0216 mgiL
0.(X)8 mgiL
Concentration
1+1 N'[-[ :::**
Minimmn 50,0(X) 1,
O.15 mgiI.+l 0%
0.15 mgiL+10%
0.002 mgiI.+l 0!:_
0.1X)9 mgiL+l 0%
Average
0.106 _FI f
0
< 0.(R)I mgiL
0.001 mgiI.
< 0.00002 mgiL
< 0.(_)2 mgiL
Maxirll [inl
0.14 NT[ ;
0
< 0.001 mgiI
0.(x)3 mgiL
< 0.00902 mgiL
< 0.002 mgiI.
Average
98.97%
> 99.99!:{
> 99.33!:{
> 99.29!:i
99.t)7%
> 76.129{
Mitfimtmi Reduction
98.61% 9.5 N'F[ ;
> 99.99!:{ > 99.95!:i
> 99.33!:i 0.010 mgiL
97.86% 0.010 mgiL
98.75% 0.0(_)2 mgiL
> 66.67:1 0.003 mgiL
* Tested using a flow rate of O.5 gpm; pressure of 60 psig; pH of 7.5 _+O.5; temp. of 68 ° -+5°F (20° -+3°C)
** Measurement in Particles/ml. Particles used were 0,5-1 microns
*** NTU=Nephelometric Turbidity units
Operating Specifications
(;apacity: certified ti)r up to 750 gallons (2,838 1); up to six months
Pressttre requirement: 40-120 psi (2.8-8.2 bar)
Telllperattlre: 33-100°F (0.6-38°(])
Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requirements
Hush new cartridge, at full flow for .3 minutes to Imrge, out trapped air.
Replace cartridge when flow becolnes too sh)w.
Special Notices
Installation instructions, parts and service availability, and standard warranty are inchtded with the prodttct when shipped.
This driI_king water s_steln inust be inaintained according to inanuf,lcturer's instructions, ii_chtding rel)lacelnent of filter
ca rtridges.
Do not use with water that is microbiologically unsate or of unknown quality without adequate disinfection before or
atter the sx:steln. Svstelns certified tor cyst reduction inav be used on disinli_cted water that inay contain filterable cysts.
The COlmmdlmnts or other substances relnoved or reduced by this water treatn/ent svsteln are not necessarily in wmr
water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was l)ertiwlned under standard laboratory conditions, actual l)erfornmnce nlav vary. Svstelns
Inust be installed and operated in accordance with inanufilcturer's reconlnlended procedures and guidelines.
Svsteln lest(d an(1 c(rtifi((1 by NSF International agaillSl Standard 42 for th( r((h|ction of
chlorin(, tast( and odor, particular( Class ] a d S a ad, d :)_ for the reduclion of (:7,'st,
lead, Lindane, Atrazine and mrbidily.
3,Iant|factm-ed for: (;(neral Electri( (_ompany, I.ouisville, KY 40225
27