11.Technical Specifications
11. Technical Specifications
Unless otherwise specified, the technical specifications applied are for XDS3000
dual-channel series only, and Probes attenuation set as 10X. Only if the oscilloscope
fulfills the following two conditions at first, these specification standards can be
reached.
This instrument should run for at least 30 minutes continuously under the
specified operating temperature.
If change of the operating temperature is up to or exceeds 5, do a
"Self-calibration" procedure (see "How to Implement Self-calibration" on P14).
All specification standards can be fulfilled, except one(s) marked with the word
"Typical".
Oscilloscope
Performance Characteristics
Instruction
Bandwidth
XDS3062A
60 MHz
XDS3102(A)
100 MHz
XDS3102AP
8 bits mode
12 bits mode
100 MHz
14 bits mode
25 MHz
XDS3202E
200 MHz
XDS3202A
8 bits mode
200 MHz
12 bits mode
150 MHz
14 bits mode
20 MHz
XDS3202
200 MHz
XDS3302
300 MHz
Vertical Resolution (A/D)
XDS3062A
12 bits
XDS3102A
12 bits
XDS3102AP
14 bits
XDS3102
8 bits
XDS3202E
8 bits
XDS3202A
14 bits
XDS3202
8 bits
XDS3302
8 bits
Channel
2 + 1 (External)
Waveform Refresh Rate
75,000 wfms/s
Multi-level Gray Scale Display &
Color Temperature Display
XDS3062A
XDS3102A
Not support
139