Brother PE545

User Manual - Page 26

For PE545.

PDF File Manual, 60 pages, Read Online | Download pdf file

PE545 photo
Loading ...
Loading ...
Loading ...
Replacing the Needle
24
Replacing the needle
Use the screwdriver and a new needle that has been
determined to be straight according to the instructions in
“Checking the needle” on page 23.
a
Press (Needle position button) once or twice to
raise the needle.
b
Place fabric or paper under the presser foot to cover
the hole in the needle plate to prevent the needle from
falling into the machine.
c
Touch .
The screen changes, and all keys and operation
buttons are locked (except ).
d
Follow step c “Replacing the embroidery foot” on
page 47 for removing the presser foot.
e
Hold the needle with your left hand, and then use a
screwdriver to turn the needle clamp screw toward
you (counterclockwise) to remove the needle.
Do not apply a strong force when loosening or
tightening the needle clamp screw, otherwise certain
parts of the machine may be damaged.
The needle clamp screw can also be turned with the
disc-shaped screwdriver.
f
With the flat side of the needle toward the rear of the
machine, insert the new needle until it touches the
needle stopper. Using the screwdriver tighten the
needle clamp screw by turning it clockwise.
g
Follow steps d to g “Replacing the embroidery
foot” on page 47 for reattaching the presser foot.
h
Touch to unlock all keys and buttons.
CAUTION
When replacing the needle, be sure to touch
on the operation panel to lock all keys
and buttons, otherwise injuries may occur if
the “Start/Stop” button or any other button is
pressed and the machine starts.
1 Needle stopper
CAUTION
Be sure to insert the needle until it touches the
needle stopper and securely tighten the needle
clamp screw with the screwdriver, otherwise
the needle may break and cause injury.
1
Loading ...
Loading ...
Loading ...