15. Technical data
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Inside base drawer of cavity.
COUNTRY OF DESTINATION: USA, Canada.
Connections
Electric 240 V 60 Hz
Gas ½” NPT at rear left-hand side
Maximum total electric load 240 V (including oven
fans, lights, etc.):
Note: The maximum input at any time is
given as the fanned grill, which is all top elements and the fan.
5.17 kW, 21 A
Dimensions
Overall height minimum 35 ⁄” (910 mm) maximum 36 ⁄” (937 mm)
Overall width 43” (1092 mm); see ‘Positioning of Cooker’.
Overall depth 28 ⁄” (723 mm)
Minimum space for cooktop 31½” (800 mm)
Weight (unpacked) 385 lbs (175 kg)
Ratings
Oven
Fan element 2.5 kW
Top element 1.2 kW
Browning element 1.15 kW
Bottom element 1.0 kW
Gas Hob
Bypass
Screw*
Natural Gas 4” WC Propane Gas 10” WC
Input Orice Input Orice
Center burners 55 17,000 btu/hr 205 17,000 btu/hr 118
Larger burners 41 12,000 btu/hr 150 12,000 btu/hr 99
Right-hand front burner 33 6,000 btu/hr 112 6,000 btu/hr 68
* The valves in this range are tted with adjustable bypass screws.The range is supplied with the bypass screws set for Natural gas.For LPG conversion the
bypass screws must be screwed all the way down.
ArtNo280-0090 Drawer Cavity & Badges