8
1. Open the cover, remove the ice basket and pour water into tank.
Keep water level below the water level mark.
2. Press “
ON/OFF
” button on the control panel to begin the ice making cycle.
3. Select the ice cube size by pressing the “SELECT” button. If the room
temperature is lower than 60
℉
, it is recommended to select small ice cube in
order to avoid ice sticking together.
4. The ice making cycle lasts approx. 6 to 13 minutes, depending on seletion of ice
cube size and the room temperature. The recommended room temperature is
50
℉ to 105 ℉
5. If water pump can’t inject water, the ice maker will stop automatically, and the
“
ADD WATER
” indicator will be on.Press “
ON/OFF
” button, fill water up to the max.
water level mark and press “
ON/OFF
” button again to turn on the unit
again.Allow the refrigerant liquid inside the compressor at least 3 minutes to
settle before restarting.
6. The ice maker stops when the ice basket is full and the “
ICE FULL
” indicator will
be on. Warning: Direct sunlight or sunlight reflection may cause infared
sensor malfunction. If the unit doesn’t stop even ice cubes obstruct
sensor, move the unit where no sunlight.
7. Change water in the water reservoir every 24 hours to ensure a reasonable
hygiene level.
If unit isn’t to be used, drain all the water and dry the tank.
USING YOUR ICE MAKER
ROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
“
ADD WATER”
indicator is on.
Lack of Water.
Stop the ice maker, fill water, and press
“ON/OFF” button again to restart the unit.
“ICE FULL” indicator is
on.
Ice is full in basket.
Remove ice from ice basket.
Continuous press “Select” button 5
seconds, the unit could make ice 10
cycles even “Ice” indicator is on.
Ice cubes stick
together.
The ice making cycle
is too long.
Stop the ice maker, and restart it when
the ice blocks melt. Select the small size
ice cube selection.
Water temperature in
inner tank is too low.
Replace the water. Temperature of water
recommended at 40
℉
-90
℉
Ice making cycle is
normal but no ice
formed.
Room temperature or
water temperature in
inner tank is too high.
The room temperature should be 50
℉
-105
℉
, water temperature should be
40
℉
-90
℉
Refrigerant in cooling
system leaks.
Verify by a qualified technician.
Pipe in the cooling
system is blocked.
Verify by a qualified technician.