26
E
Specications
DW0165N & DW0165S DW0330SN
Range 6in to 165ft
(0.15m to 50m)
6in to 330ft
(0.15m to 100m)
Measuring Accuracy
1
up to 10m: 1/16in (1.5mm)
10m-30m: 0.078in/5/64in) additional (+/- 0.15mm/m)
>30m: +/- 0.002in/ft (+/- 0.2mm/m)
Resolution
2
1/16in (1mm)
Laser Power Class 2 ≤ 1mW @ 620-690nm or
Class 3R ≤ 5mW @ 620-690nm
Laser Automatic Switch-off 30s
Unit Automatic Switch-off By default, 90s. User can set to 30s, 60s, or 300s
Continuous Measuring Yes
Area Yes
Volume Yes
Pythagoras 2-Point Yes
Endpiece to measure from
corners
3
Yes
Battery Life (3 x AAA) Up to 3000 Measurements
(2500 with
; DW0165S & DW0330SN)
Dimension (H x D x W) 4.72 x 1.91 x 1.02in (120 x 48.5 x 26mm)
Weight (with Batteries) 9.88oz (280g)
Storage Temperature Range 14° F ~ 140° F (-10° C ~ +60 C)
Operating Temperature Range 32° F ~ 104° F (0° C ~ +40° C)
1
Measuring Accuracy depends on the current conditions:
Under favorable conditions (good target surface and room temperature), up to 33ft
(10m).
Under unfavorable conditions (bright sunlight, a very weak reecting target surface, or
large temperature uctuations), the error can increase by to ± 0.003 in/ft (± 0.25mm/m)
for distances over 33ft (10m).
2
Resolution is the nest measurement you can see, 1/16" (1mm).
3
Flip open the endpiece at the bottom of the tool when you need to t the tool into corners or
grooves that are not at 180° angles. If a corner is at 90°, the endpiece can be used to hold
the tool up against something.
Loading ...
Loading ...
Loading ...