Loading ...
Loading ...
Loading ...
INSTALLATION - 2391477A432/A
e
Gas connection
Carefully screw the connector 3 to the
appliance’s gas connector 1 (1/2” thread
BSP), placing the supplied seal 2 between
them.
For Natural Gas connect the appliance gas
inlet (1 + 2 + 3) to the pressure regulator (4 - not
supplied).
For Universal LPG connect the appliance gas
inlet (1 + 2 + 3) to the test point adaptor (5 - not
supplied).
This appliance must be installed by an
authorised person in accordance with this
instruction manual, AS/NZS 5601.1 – Gas
installations (installation and pipe sizing), local
gas fitting regulations, local electrical
regulations, local health regulations, Building
Code of Australia and any other government
authority.
This appliance is suitable for connection with
rigid pipe or flexible hose. The isolating manual
shut-off valve connection point must be
accessible when the appliance is installed.
Flexible hose assembly must be certified to AS/
NZS 1869 class B or D, be of appropriate
internal diameter for the total gas consumption
(10mm), be kept as short as possible (not
exceeding 1200mm), must not be in contact
with the floor or any hot surface or sharp
surface. The hose assembly must not be subject
to strain, abrasion, kinking, deformation, contact
with any other appliance or accidental contact
with oven flue outlet of an under bench oven.
Gas leakage and operation of the appliance
must be tested by the installer before leaving.
Check burner flames are blue in colour, stable
and completely ignite at both high and low
flame settings with no appreciable yellow
tipping, carbon deposition, lifting, floating,
lighting back or objectionable odour. Test
burners individually and in combination. When
satisfied with the operation of the cooker,
please instruct the user on the correct method of
operation
Natural Gas: the pressure regulator must be
fitted to the appliance inlet connection. Gas
pressure must be adjusted to 1.0 kPa when
approximately 50% of the burners are on high
flame, the appliance test point is located on the
regulator.
Universal LPG: gas pressure must be checked to
confirm the appliance operating pressure is
2.75 kPa.
1. Disconnect power.
2. Light the auxiliary burner and set to high
flame. Ensure all other burners are off.
3. Zero manometer, then apply flexible tubing
to seal over the Rapid burner injector, hold
securely in place and check the gas
pressure by pressing in the corresponding
burner control knob in, then turning to high
flame position.
4. If the pressure is 2.75 kPa, reassemble the
burner and perform the final checks as per
this instruction manual.
5. If the pressure is not 2.75 kPa, disconnect
the appliance and check/adjust/replace
the LPG cylinder regulator(s) as appropriate
in accordance with AS/NZS 5601.
Patent 2015101170. For enquires contact
Gas Approval Consulting Pty Ltd Smeg
licence 037 for GSCS20265
See General safety instructions.
Loading ...
Loading ...
Loading ...