837915
OPEN DOOR ALARM
If the refrigerator or freezer compartment door is open for too long, an
acoustic alarm (repetitive beep) will be activated. If the alarm is not deactivated
manually, it will be sounded for 10 minutes.
The appliance will continue to operate as if the door was closed.
Switching off the alarm: To switch off the alarm, close the door.
If you switch off the alarm by pressing any key, the alarm will be
reactivated in 4 minutes if the door is still open.
i
POWER SUPPLY FAILURE ALARM
If the temperature in the appliance
reached the alarm level during
the power outage, then the high
temperature alarm will be activated
when power supply is restored.
Acoustic alarm will be sounded, and
PF will flash on the display unit B3.
To acknowledge and turn off the
acoustic alarm signal, press any key.
The highest measured temperature
of the freezer compartment will be
displayed on the B3 display unit, and
the B1 symbol will light up.
The next time you press the B key,
the highest measured temperature of
the refrigerator compartment will be
displayed, and the B2 symbol will be
lit up.
When you press the B key again, the power supply failure alarm will be finally
deactivated, and the set temperature for the selected compartment will appear
on the B3 display unit.
If the high temperature alarm is activated at the same time, it will operate as
described in the chapter High Temperature Alarm, after you have deactivated
the power supply failure alarm.
If you leave the door open for more than 10 minutes, then the alarm will
stop. Appliance operation switches to safe mode in order to provide
sufficient cooling and prevent food spoilage despite the open door.