INSTALLATION GENERAL
WARNING
This heater must not be installed where curtains or other combustible materials could come into
contact with it.
In some cases curtains may need restraining. Other clearances are shown in the diagram.
THIS HEATER IS NOT DESIGNED TO BE BUILT INTO BOOKCASES OR SHELVES.
Ensure that the area in which the appliance is installed has adequate xed ventilation, this xed
ventilation must be provided as detailed in AS/NZS5601.
An EARTHED power point, and bayonet gas connection
must be close enough to where the heater will be used
to avoid stretching the connection.
NOTE
After installation checks have been completed connect gas and power and follow ignition
instructions.
150mm
150mm
150mm
1000mm
150mm
150mm
150mm
1000mm
(to furniture)
INSTALLATION INSTRUCTIONS