Installation Instructions
INSTALLING THE WATER LINE
BEFORE YOU BEGIN
Recommended copper water supply kits are WXSX2,
WXSX3 or WXSX4, depending on the amount of tubing
you need, Approved plastic water supply lines are GE
SmartConnect T=Refrigerator Tubing (WXOSX10002,
WXOSX10006, WXOSX10015 and WXOSX10025),
When connecting your refrigerator to a GE Reverse
Osmosis Water System, the only approved installation
is with a GE RVKit, For other reverse osmosis water
systems, follow the manufacturer's recommendations,
If the water supply to the refrigerator is from a Reverse
Osmosis Water Filtration System AND the refrigerator
also has a water filter, use the refrigerator's filter bypass
plug, Using the refrigerator's water filtration cartridge in
conjunction with the Re filter can result in hollow ice cubes
and slower water flow from the water dispenser,
This water line installation is not warranted by the
refrigerator or icemaker manufacturer, Follow these
instructions carefully to minimize the risk of expensive
water damage,
Water hammer (water banging in the pipes)in house
plumbing can cause damage to refrigerator parts and
lead to water leakage or flooding, Call a qualified plumber
to correct water hammer before installing
the water supply line to the refrigerator,
To prevent burns and product damage, do not hook
up the water line to the hot water line,
If you use your refrigerator before connecting the water
line, make sure the icemaker power switch is in the OFF
position,
Do not install the icemaker tubing in areas where
temperatures fall below freezing,
All installations must be in accordance with local plumbing
code requirements,
Connect to potable water supply only,
WHAT YOU WILL NEED
. Copper or GE SmartConnect '°' Refrigerator Tubing kit,
1/4" outer diameter to connect the refrigerator to the
water supply, If using copper, be sure both ends of the
tubing are cut square,
To determine how much tubing you need: measure
the distance from the water valve on the back of the
refrigerator to the water supply pipe, Be sure there is
sufficient extra tubing to allow the refrigerator to move
out from the wall after installation,
GESmartConnect T=Refrigerator Tubing Kits are available
in the following lengths:
2' (0,6 m) - WXOSXl0002
8' (2,4 m) - WXOSXl0006
15' (4,6 m) - WXOSX10015
25' (7,6 m) - WXOSX10025
WHAT YOU WILL NEED (CONT.)
NOTE: The only GE approved plastic tubing is that
supplied in GE SmartConnect TM Refrigerator Tubing
kits. Do not use any other plastic water supply line
because the line is under pressure at all times. Certain
types of plastic will crack or rupture with age and
cause water damage to your home.
, A GE water supply kit (containing tubing, shutoff valve
and fittings listed below) is available at extra cost from
your dealer or from Parts and Accessories,
800,626,2002,
. A cold water supply. The water pressure must be
between 20 and 120 p,s,i, (1,4-8,2 bar) on models
without a water filter and between 40 and 120 p,s,i,
(2,8-8,2 bar) on models with a water filter,
. Power drill.
.1/2" or adjustable wrench.
. Straight and Phillips blade screwdriver.
, Two 1/4 "" outer diameter compression nuts and
2 ferrules (sleeves)--to connect the copper tubing
to the shutoff valve and the refrigerator water valve,
OR
. If you are using a GE SmartConnect TM Refrigerator
Tubing kit, the necessary fittings are preassembled to
the tubing,
. If your existing copper water line has a flared fitting
at the end, you will need an adapter (available at
plumbing supply stores) to connect the water line to
the refrigerator OR you can cut off the flared fitting
with a tube cutter and then use a compression fitting,
Do not cut formed end from GE SmartConnect TM
Refrigerator tubing,
, Shutoff valve to connect to the cold water line,
The shutoff valve should have a water inlet with a
minimum inside diameter of 5/32" at the point of
connection to the COLD WATER LINE. Saddle-type
shutoff valves are included in many water supply kits,
Before purchasing, make sure a saddle-type valve
complies with your local plumbing codes, Install the
shutoff valve on the nearest frequently used drinking
water line,