Page 11
Maintenance: Scale Removal and Sanitation
Note: Following this procedure will reset the de-scale
and sanitize light.
Preparing to clean
1. Remove both the front and right panels.
2. Push and release the OFF button.
3. Remove ice from bin or dispenser.
4. Turn the water supply to the oat valve OFF by
turning the knob 1/4 turn CCW.
5. Drain the water reservoir into a bucket using the
vent tube.
6. Drain the evaporators by disconnecting the
evaporator water supply tube from the water
reservoir. Take the evaporator water supply tube
o󰀨 the tube support bracket on the front right post
and lower to fully empty both evaporators. (see
diagram below)
7. Put the evaporator water supply tube back
on top of the tube support bracket, reconnect
the evaporator water supply tube to the water
reservoir, and return the vent tube to it’s original
collar bracket.
8. Loosen the thumb screw and raise the water
reservoir from the “make ice” position to the
“clean” position.
9. Remove the water reservoir cover.
10. Remove both ice chute covers.
Scale Removal
11. Prepare a solution of 32oz. Scotsman Clear One
scale remover and 32oz. 95-115 °F. potable water.
12. Using a small cup for precise pouring, add the
scale remover solution into the reservoir until the
solution comes out of top of the evaporators at the
extruders, about 2qts.
13. Push and release the Clean button: C is displayed
and the Time to Clean light blinks. The augers
will turn and circulate the scale remover for 30
minutes before shutting o󰀨. No ice is made during
the cleaning cycle.
14. Drain the water reservoir and evaporators by
repeating steps 5-7.
Sanitize
15. Prepare a solution of sanitizer. Mix 4 oz. of
NuCalgon IMS and 2.5 gallons of 95-115 °F.
potable water to create a 200 ppm solution.
16. Using a small cup for precise pouring, add the
sanitizer solution into the reservoir until the
solution comes out of top of the evaporators at
the extruders, about 2qts. Reserve any exess
sanitizer.
17. Allow the sanitizer to soak while steps 18-22 on
the following page are completed, or at least 60
seconds.
Ice machine scale remover
contains acids. Acids can
cause burns.
If concentrated cleaner
comes in contact with
skin, ush with water. if
swallowed, do NOT induce
vomiting.
Give large amounts of
water or milk. Call Physician
immediately. Keep out of the
reach of children.
CLEAN
MAKE
ICE
Vent Tube
Water Supply Knob
Evaporator Water
Supply Tube
Tube Support Bracket
Thumb Screw
Water Reservoir