Bluelab BLU2100E TRUNV2 Truncheon Nutrient Meter, Digital Conductivity Tester in Water Tool for Hydroponic System and Indoor Plant Grow & General Hydroponics pH Control Kit for a Balanced Nutrient Solution

User Manual - Page 5

For BLU2100E.

PDF File Manual, 9 pages, Download pdf file

Loading ...
Loading ...
Loading ...
4.0 Troubleshooting guide
Trouble Correction
Truncheon Meter turns off
before reading taken.
Take out of solution for 3-5 seconds.
Dip in solution again and take reading.
Truncheon Meter not lighting
when dipped in solution.
Clean the probe. If this is unsuccessful, replace
batteries. Do not use rechargeable batteries.
Truncheon Meter gives low
readings.
Clean the probe.
Ensure unscented cleaner is used eg. plain ‘Jif’, ‘Soft
Scrub’, ‘Liquid Vim’, ‘Cif’ or ‘Viss’.
5.0 Technical specications
Range
2 – 36 CF 140 – 2520 ppm (EC x 700)
0.2 – 3.6 EC 100 – 1800 ppm (EC x 500)
Resolution 1 CF, 0.1 EC, 70 ppm (700), 50 ppm (500)
Accuracy
± 0.1 EC, ± 1 CF, ± 50 ppm (1385 ppm at 500 ppm),
± 70 ppm (1939 ppm at 700 ppm)
Temperature compensation Automatic
Operating temperature 0 - 50 °C, 32 - 122 °F
Calibration Factory calibrated
Limitation of Liability
Under no circumstances shall Bluelab Corporation Limited be liable for any claims,
losses, costs and damages of any nature whatsoever (including any consequential loss)
that result from the use of, or the inability to use, these instructions.
English
4
Loading ...
Loading ...
Loading ...