LG Electronics DLEX8980V Lg 9.0 Cu. Ft. Mega Capacity Smart Wi-fi Enabled Front Load Electric Dryer With Turbosteam And Built-in Intelligence

User Manual - Page 22

For DLEX8980V.

PDF File Manual, 60 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
22 INSTALLATION
The male end of each section of exhaust duct
must point away from the dryer.
Use duct tape on all duct joints.
Insulate ductwork that runs through unheated
areas in order to reduce condensation and lint
buildup on duct surfaces.
Incorrect or inadequate exhaust systems are not
covered by the dryer warranty. Dryer failures or
service required because of such exhaust
systems will not be covered by the dryer
warranty.
Correct Venting
Incorrect Venting
Connecting Gas Dryers
WARNING
To reduce the risk of fire or explosion, electric
shock, property damage, injury to persons, or
death when using this appliance, follow
requirements including the following:
Electrical Requirements for Gas
Models
WARNING
This dryer is equipped with a three-prong
grounding plug for protection against shock
hazard and should be plugged directly into a
properly grounded three-prong receptacle. Do
not cut or remove the grounding prong from
this plug.
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
For personal safety, this dryer must be properly
grounded.
This dryer must be plugged into a 120-VAC, 60-
Hz. grounded outlet protected by a 15-ampere
fuse or circuit breaker.
Where a standard 2-prong wall outlet is
encountered, it is your personal responsibility
and obligation to have it replaced with a
properly grounded 3-prong wall outlet.
Gas Supply Requirements
WARNING
DO NOT attempt any disassembly of the dryer;
disassembly requires the attention and tools of
an authorized and qualified service technician or
company.
DO NOT use an open flame to inspect for gas
leaks. Use a noncorrosive leak detection fluid.
Gas pressure must not exceed 8-inch (20.4 cm)
water column for NG, or 13-inch (33.1 cm) water
column for LP.
Isolate the dryer from the gas supply system by
closing its individual manual shutoff valve during
any pressure testing of the gas supply at
pressures greater than 3.5 kPa.
Supply line requirements: Your laundry room
must have a rigid gas supply line to your dryer.
In the United States, an individual manual
shutoff valve MUST be installed within at least 6
ft. (1.8 m) of the dryer, in accordance with the
National Fuel Gas Code ANSI Z223.1 or Canadian
gas installation code CSA B149.1. A 1/8-inch NPT
pipe plug must be installed.
If using a rigid pipe, the rigid pipe should be 0.5-
inch IPS. If acceptable under local codes and
ordinances and when acceptable to your gas
supplier, 3/8-inch approved tubing may be used
where lengths are less than 20 ft. (6.1 m). Larger
tubing should be used for lengths in excess of 20
ft. (6.1 m).
To prevent contamination of the gas valve,
purge the gas supply of air and sediment before
connecting the gas supply to the dryer. Before
tightening the connection between the gas
supply and the dryer, purge remaining air until
the odor of gas is detected.
Loading ...
Loading ...
Loading ...