Figure 3-30 Wired zone
Step 3 Tap the wired zone name to congure the zone.
Table 3-9 Description of wired zone parameters
Parameter Description
Zone No. The number cannot be modied.
Zone Type
Select the corresponding type according to the detector type, including
IR, gas, smoke detector, emergency button, door detector, burglar,
perimeter and doorbell. Dierent types have dierent icons displayed.
NO/NC
Select NO (normally open) or NC (normally closed) according to the
detector type. It must be the same as the detector type.
Alarm Status
Instant Alarm : When armed, if an alarm is triggered, the device
produces a siren at once and enters the alarm status.
Delay Alarm : When armed, if an alarm is triggered, the device enters
the alarm status after a specied time, during which you can disarm
and cancel the alarm.
Bypass : Alarms will not be triggered in the area. After the area is
disarmed, it will be restored to its normal working status.
Remove : The area is invalid during arming and disarming.
24 Hour : Alarms will be triggered all the time in the area, regardless
of whether it is armed or disarmed.
A zone in the Remove status cannot be bypassed.