3. Operation
Power: The refrigerator can be powered by a multi-voltage system utilising either 12/24
Volts or with the included 240V adaptor. The electronic module controls the compressor
and has the added function of a three stage battery protection. When the input voltage
drops below the minimum, the compressor will cut out; when the voltage comes back
up to the cut-in value, the compressor will restart automatically.
Battery Protection: The SECOP compressor requires approximately 11.0 Volts (12 Volt
System) or 23.0 Volts (24V System) to operate. If the voltage drops below this the fridge
will stop running.
Cable Specification: The DC cables must have a suitable cross-section for their length
(measured from the battery to the unit), according to this table:
Cable Thickness (Area) 12V Max Cable Length 24V Max Cable Length
(mm
2
) AWG (m) () (m) ()
2.5 13 2.5 8 5 16
4 11 4 13 8 26
6 9 6 20 12 39
10 7 10 33 20 66
DOWN UNDER SERIES
RECOMMENDED TEMPERATURE SETTINGS
Fridge 2°C
Freezer -16°C
COMPRESSOR SPEED SETTINGS
Eco Recommended for ambient temperatures of 30°C or less.
Max Recommended for ambient temperatures of 30°C or more.
For Maximum Eiciency
Use the included baskets to ensure air circulation freely around the cabinet.
Ensure the vents are not obstructed as to allow maximum airflow.
Refrain from unnecessary opening of the unit.