SOLAR Power Inverter USER’S MANUAL
15
Problem: Low Battery Alarm on Continuously
Answer: The voltage of the 12 Volt power source may have dropped below 10.5 Volts – check 12 Volt power
source voltage and recharge as needed.
Answer: Poor or weak 12 Volt power source – recharge or replace the battery.
Answer: Inadequate power delivery from the 12 Volt power source – check the connections between
the 12 Volt power source and the power inverter (see “Connect the DC Input Cables”).
Problem: Poor Television/Audio Device Reception
Answer: Refer to “Suggestions When Using Your Power Inverter to Power Television and Audio Devices”
section within this Operator’s Manual.
Specifications
Model No. PI30000X
Electrical Specifications
Nominal DC Inpu t 12VDC
Input Voltage Range 10 - 15VDC
Low Voltage Alarm (10.5V) YES
Low Voltage Shut-Down (10V) YES
Over Voltage Shut-Down (15V) YES
Over Heat Protection (149˚F) YES
Cooling Fan YES
Overload Protection YES
Short Circuit Protection YES
No Load Current Draw <0.8 A
DC Fuse 18 x 20A
AC Output Voltage 115VAC (RMS) +/-10%
AC Output Frequency 60 Hz +/-3 Hz
Output Waveform Modified sine wave
Maximum continuous AC Power 3000W
Maximum peak AC Power 6000W
Peak Capacity (Seconds) 1
Efficiency >85%
Operating Temp. Range
23˚-104°F (-5°-40°C)
LED Indicators Power, Fault
Power Display Yes
AC Receptacle Triple
Individually Switched Outlets Yes
Remote Switch Yes
DC Connection Hardwire
Dimensions (H x W x L) 16.5” x 10.3” x 3.7”
Weight 13.20 lbs. (5.99 kg)
Warranty One year limited