Trouble Shooting Method
For some troubles, the machine buzzer will ring and alarm, and the indicator will flash.
Troubles
Indicator Light
No indicator
No indicator
No indicator
No indicator
Possible Cause Solution
Breakdown
The plug is badly connected
to the socket or the switch is
not activated.
The socket is dead or the fuse
is broken.
The current process is lost
for power failure
The voltage is too low or too
high
Connect the plug properly or
activate the switch
Contact the authorized technician
Reuse only when power failure
is eliminated
Remove the plug and reuse it when
the voltage comes to normality.
E3
E1
E4
Standing
drain
A conflict
between the
tub and the
cabinet
during
spinning
Insufficient
water supply
E6
The drain hose is blocked or
hung up over 0.9m, and the water
cannot finish draining within 7 min
Check the drain hose,open the
lid and then close it to continue
drain process.
The clothes are not laid evenly
in the tub.The machine will try
to make a automatic check
and ajustment for 2 times,or if
nothing available ,an alarm
will be given.
Open the lid,distribute the clothes
evenly in the tub and then close
the lid to continue.
The tap is closed,water supply
is cut off or water pressure is
too low,so the water fails to
reach to the desired level within
30 minutes.
Open the tap or use the machine
after the water pressure comes
to normal.Open the wash lid,
close it and restart to input water.
Abnormal
water level
sensor
The sensor fails for short or
open current,etc.and an alarm
will be given.
Contact the authorized technician.
E7
E9
Unstoppable
Memory chips
break down
The chip cannot be accessed.
inlet or
automatic
drain
Abormalities occur in PCB,
inlet valve or water level
sensor
Cut off the power after draining ,
and try to contact with the
authorized technician.
Fail to power
off or power
on
Unending process
or no indicator
PCB is broken.
Contact the authorized technician.
Turn off the machine.
- 14 -