6
5/22 Rev. E 171551
When moving the Capsule Pak ECO into position, use caution not to damage the gasket material underneath the
evaporator section. It is recommended to slide the Capsule Pak ECO on a sheet of cardboard over the top of the
walk-in until it is in the desired location. The cover over the evaporator section of the Capsule Pak ECO may be
removed to assist with locating the Capsule Pak ECO over the hole in the ceiling panel.
Once the Capsule Pak ECO is located over the ceiling hole it should be secured in place by the four latches in the
ceiling panel hole (see figure 3).
Seal the seam between the Capsule Pak ECO and the ceiling panel with the silicone supplied (see figure 4).
Replace the diffuser panel. When re-installing the diffuser panel, make sure the divider section on the panel
seals against the black gasket on the bottom middle of the Capsule Pak ECO. Some adjustment may be required
by simply bending the divider slightly forward or backward so it contacts the black gasket. This will prevent any
re-circulation of air and improve the efficiency of the Capsule Pak ECO.
SET-UP AND INSTALLATION
CEILING MOUNTED SELF-CONTAINED CAPSULE PAK ECO™ REFRIGERATION SYSTEM
CAUTION
This unit uses a flammable refrigerant. Use care when handling and operating to avoid damaging the
refrigerant tubing or increasing the risk of a leak.
! WARNING
This appliance must be installed in accordance with all applicable national, state and local regulations. This
appliance is heavy. Use care when lifting and positioning. Work in pairs when needed to prevent injury or damage.
This appliance is not intended for outdoor use. The ambient temperature should be at or below 90°F and a relative
humidity of 55% or less. At higher temperature or humidity conditions, the performance of these cases may be
affected and the capacity diminished. These unit should not be positioned where it is directly exposed to rays
of sun or near a direct source of radiant heat or airflow. This will adversely affect the unit and will result in poor
performance. Operating conditions range from 45°F to 100°F (7°C to 38°C). Operating this appliance outside its
range and installation requirements may affect performance and warranty coverage.
General Installation Instructions
Figure 3
Figure 4