Tripp Lite GC1000L NEW Portable Power Station - 1000W, Lithium-Ion LFP, AC, DC, USB-A, USB-C, QC 3.0

Owner's Manual - Page 5

For GC1000L NEW.

PDF File Manual, 24 pages, Read Online | Download pdf file

GC1000L NEW photo
Loading ...
Loading ...
Loading ...
5
Powering Devices
Powering 12V DC Devices
To provide power to 12V DC devices (such as a headlamp, fan, etc.), plug your device into the 5.5 mm 12V DC output or
Cigarette Lighter Adapter (CLA).
Short-circuit/overpower protection: The DC output rated power is 85W. If the DC output is short-circuited or overpowered
(load power >85W), the unit will shut down. If this occurs, press the DC switch to resume use.
Notes:
Before attempting to power your device, confirm whether your DC 12V device supports charging with a 5.5 mm DC header interface
(the diameter of the DC port is 5.5 mm). Otherwise, you may be unable to connect with the unit’s DC output and an adapter may be
needed. For more information, consult the device manufacturer’s documentation.
The DC output voltage range is 12V with a rated output current of 7A. DC output voltage drops while the battery capacity drops due
to chemical characteristics of the battery. If your device does not have a built-in input voltage stabilizing function, it may shut down
when input voltage is too low. If this occurs, unplug your device and charge the unit.
Powering AC Devices
WARNING! The AC outlets, AC voltage and frequency are different according to different countries. Please
check first whether the product specifications are consistent with the device specifications before use.
Connect the power cable plug of the electrical device to the AC outlet, then switch on the POWER AC button. The unit will
start providing power to your devices.
Short-circuit/overload protection: During an AC output short-circuit or overload (>1000W), the AC output function will stop.
If this occurs, remove the load and press the AC button to reactive the unit.
For some electrical appliances, such as refrigerators, ice machines, laser printers, etc., there will be a short peak power
(up to 1000W or above) upon starting up. This may activate the overload protection feature. If this occurs, remove the
device and press the AC button to reactivate the unit.
Note: Turn off the AC switch to save energy if the AC output function is not needed.
5.5 mm DC 12V device
(power <84W)
Cigarette Lighter Adapter (CLA) device (vacuum,
inflation pump, electric wrench, compact fridge, etc.)
Limited wattage: <1000W (lamp, electric fan, TV, etc.). The
AC will shut down when it is short circuited or the power is
overloaded. If this occurs, remove the device and the unit will
recover, then press the AC output button to switch on the AC
output.