Napoleon RXT425SIBPSS-1-FI ROGUE® XT 425 SIB WITH INFRARED SIDE BURNER

Owner's Manual - Page 8

For RXT425SIBPSS-1-FI. Series: ROGUE SERIE
Also, The document are for others Napoleon models: RB425*, R365*, R425*, R525*, RSE425*, RSE525*, RSE625*, RXT365*, RXT425*, RXT525*, RXT625*

PDF File Manual, 24 pages, Read Online | Download pdf file

RXT425SIBPSS-1-FI photo
Loading ...
Loading ...
Loading ...
8
| Getting Started
Napoleon.com | Rogue® Series Grills
Getting Started
WARNING! Never use an open flame to check for gas leaks. Sparks or flames will cause a fire, explosion, damage
to property, serious physical injury, or death.
WARNING! Only use the pressure regulator and hose assembly supplied with the
grill, or one in conformity with local codes.
!
LEAK TEST
Why and When to Leak Test?
A leak test confirms no gas is escaping after you
connect the hose to the gas supply.
Each time the tank is refilled and reinstalled,
ensure that there are no leaks in the fitting where
the regulator connects to the tank.
Leak test this grill before use, annually, and when
any gas components are replaced.
Leak Test Steps
1. Do not smoke while performing the test.
2. Remove all sources of ignition.
3. Turn all burner controls to the off position.
4. Turn the gas supply valve on.
5. Brush a half-and-half solution liquid soap and
water onto all joints and connections of the
regulator, hose, manifolds, and valves.
6. Bubbles indicate a gas leak.
If you find a leak
1. Tighten any loose joints.
2. If the leak cannot be stopped, immediately shut off the gas
supply and disconnect the grill.
3. Have the grill inspected by a certified installer, or dealer.
4. Do not use the grill until the leak has been fixed.
STOP
Loading ...
Loading ...
Loading ...