19
“E3, “E4,
“E5 or “E7”.
E1 or E2 indicates that the air
temperature sensor has failed.
E3 or E4 indicates that the defrost
sensor in the evaporator has failed.
E5 indicates defrost heater failure.
E7 indicates door switch failure.
The alarm
sounds and
the
temperature
display
flashes.
Has a drawer been open for longer than
60 seconds? If not, then the temperature
has risen higher or fallen lower than the
temperature that has been set. This could
be due to:
The appliance drawers being opened
too often.
The ventilation opening being covered
or too dusty.
A lengthy interruption in the power
supply.
A large amount of food has been added
to the unit.
The icon “--” is
lit and flashing
in the
temperature
display.
The display temperature is out of
range.