10. INSTALL THE HOOD
CAUTION
DO NOT REMOVE the protective plastic film covering the decorative flue (upper & lower) yet.
1. Align the hood and center it above the hood mounting bracket. Gently lower the
hood until it securely engages the bracket.
2. Level the hood.
3. With the hood hanging in place, mark both hole locations on wall (2 embossed
holes on back of hood; see illustration at right).
4. Remove the hood.
5. Drill through both marked holes on wall using a 3/16” drill bit. Insert the included
drywall anchors into the drilled holes (one for each hole).
6. Hang the hood to the wall bracket.
7. Secure the hood to the wall using 2 no. 8 x 3/4” screws and 2 washers.
WARNING
!
BE CAREFUL when installing the decorative flue and hood, they may have sharp edges.
HOLE LOCATIONS
Ø 3/16” TYP.
HD0810A
SIDE VIEW
NOTE: ILLUSTRATION ABOVE REPRESENTS HORIZONTAL
EXHAUST CONFIGURATION, BUT IT ALSO APPLIES TO
VERTICAL EXHAUST CONFIGURATION.
11. REINSTALL BLOWER (HORIZONTAL DISCHARGE ONLY)
1) Position the blower on the inner back of the hood, as shown on the right.
2) Using a 5/16” socket, or a Robertson or a Phillips no. 2 screwdriver and the 4 screws
previously removed, secure the blower to the hood.
NOTE: In order to ease installation, before mounting the blower, prepare the screw holes
by screwing all 4 screws without the blower, then remove and mount the blower.
3) Plug the blower connector back in and plug hood power cord into the outlet.
HD0829
RIGHT SIDE
MOUNTING
SCREW
LOCATIONS
12. VERTICAL DISCHARGE DUCT CONNECTION
Plug hood power cord into the outlet. Slide a 6” round or a 3¼” x 10” metal duct over the adapter/damper on the hood. Use metal foil duct
tape to seal the joint.
HJ0148