Installation Instructions
[] INSTALLING THE ANTI-TIP
DEVICE
-AWARNING!
Range, must be secured with an approxed Anti-Tip
device.
Unless properly installed, the range could be tipped
b) )ou or a child standing, sitting or leaning on an
oi)en dooi;
_Mter installing the Mlfi-Tip device, xerif}, that it is in
place b) careflflly attempting to tilt file range fi)rward.
This range has been designed to meet all recognized
industry tip standards fi_r all nmmal conditions.
The use of this device does not prechMe tilI) )in,,_ of
the range when not properly installed.
If the Anti-Tip dexice sui_plied with tile range does
not fit this application, use the tmixe_sal Anti-Tip
device _ B2X7909.
A. Mark the wall where the RIGHT EDGE _ff the range
is to be located. Be sm'e to allow fi_r the cotmtertop
overhang if you intend to install the range next to
cabinets.
SIo_ed head
screw
Approx. 28
Marked edge of range
B. I,ocate the outside edge of the device 2_" toward
the center of the range fl'om the marked edge of
the range.
C. Using the device as a template, mark the position of
the hole fi_r the screw.
D. For wood construction, drill a pilot hole at an an,de
of 20 degrees fl'om the horizontal. A nail or awl
max be used if a drill is not axailable.
Motmt the Anti-Tip device with the screw provided.
For celnent or concrete constrtlction, VOII will need
a ]/4" x ] ½" lag bolt and a ]/2" O.D. sleeve anchor;
which are not provided. Drill the recommended size
hole fi)r the hardware.
[] INSTALLING THE ANTI-TIP
DEVICE (CONT.)
Wallboard
Wood screw
Back of range
lnst;fll the sleeve anchor into the drilled hole and then
install the lag bolt through the device. Tile bolts must be
properly tightened as recommended tot the hardware.
E. Slide the range against the wall, and check tot proper
installation by grasping the ti'ont edge of the cooktop
and carefully attempting to tilt the range forward.
WHEN ALL HOOKUPS ARE
COMPLETED
Make sure all controls are left in the off position. Make
sure the flow of combustion and ventilation air to the
rmlge is mlobstructed.
CONVERTING TO LP GAS (or
converting back to natural gas from LP)
This rmlge leaves the factory set for use with natural gas.
If you want to convert to LP gas, the conversion must be
performed by a qualified LP gas h_staJler.
The conve_ion instructions and LP orifices can be t0tmd
attached to the range next to the pressm'e regulator:
Kee I) these instructions and the o_ifices in case wm want
to convert back to natm'al gas.