RCF HD 12-A MK5 ACTIVE TWO-WAY SPEAKER

OWNER’S MANUAL - Page 9

For HD 12-A MK5. Also, The document are for others RCF models: HD 10-A MK5

PDF File Manual, 28 pages, Read Online | Download pdf file

HD 12-A MK5 photo
Loading ...
Loading ...
Loading ...
9
EN
5. FAILURE INDICATION AND SAFETY
The microprocessor is able to signal three different kinds of failure by flashing the “Limiter” red LED on the amplifier panel before the lighting up
of the “Power status” green LED
The three types of failure are:
- WARNING: a non severe error or auto-ripristinate malfunction is detected and the performance of the speaker is not limited�
- LIMITATIONS: an error is detected and the performance of the speaker is limited (the sound level is reduced by 3 dB)� This does not affect the
operation of the speaker since it continues to operate� However, it is necessary to call the service centre to solve the issue
- FAILURE: a severe malfunction is detected� The speaker switches to “mute”�
FLASHING INDICATION:
1 or 2 : Warning
3 or 4 : Limitation
5 to 8 :Failure In case of failure, the “Ready” green LED remains off
Perform the checks listed below:
- check if the speaker is properly connected to the power supply
- make sure that the power supply is of correct voltage
- check that the amplifier is not overheated
- disconnect the speaker from the mains power supply, wait for a few minutes and connect it again� If after these tests the red “LIMITER” LED is
still on, please contact an authorised service centre